Double effect and double stage absorption refrigeration cycle thermodynamic study

Absorption refrigeration systems are thermal cycles activated by heat in which the presence of mechanical work is practically negligible. These cycles have become more attractive because they have low electricity consumption, low operating costs, and reduced environmental impact. They do not use gases harmful to the ozone layer and can be integrated into cogeneration systems. These systems show versatility in heat sources, operating solar energy and combustion gases from industrial processes. This study aims to study the performance of double-effect and double-stage absorption refrigeration cycles with different input parameters, using the NH 3 -H 2 O solution as the working fluid. A thermodynamic model of the cycle was developed by applying the law of conservation of mass and the First Law of Thermodynamics. The model was implemented and solved using the EES software. Operational temperatures of condenser, evaporator, generator and absorber, were varied. The thermodynamic analysis showed that the coefficient of performance (COP) of the cycle was higher for higher evaporation temperatures, lower condensing temperatures and lower absorber outlet temperatures. Considering all the simulations performed, the COP values were between 0.63 and 0.84, with the evaporation temperature being the most influential parameter of the cycle. It was observed that higher condensing temperatures require higher minimum temperatures in generator 2 due to heat transfers limitations that occur internally in the cycle. The influence of each stage of the cycle on the generation of refrigerant vapor varied with the cycle operating parameters, with the first stage being responsible for approximately 70 % of the mass flow generated.

Authors

Institutions

Publication Details

Journal
International Journal of Thermofluids
Published
2025-04-09
DOI
https://doi.org/10.1016/j.ijft.2025.101203
Citations
4
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
2.85
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Double effect and double stage absorption refrigeration cycle thermodynamic study

William Galiotto, Andrés Z. Mendiburu, Sujit Kumar Verma
4 citations
International Journal of Thermofluids
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
2.85
article

Double effect and double stage absorption refrigeration cycle thermodynamic study

William Galiotto, Andrés Z. Mendiburu, Sujit Kumar Verma
article en
4 citations

Abstract

Absorption refrigeration systems are thermal cycles activated by heat in which the presence of mechanical work is practically negligible. These cycles have become more attractive because they have low electricity consumption, low operating costs, and reduced environmental impact. They do not use gases harmful to the ozone layer and can be integrated into cogeneration systems. These systems show versatility in heat sources, operating solar energy and combustion gases from industrial processes. This study aims to study the performance of double-effect and double-stage absorption refrigeration cycles with different input parameters, using the NH 3 -H 2 O solution as the working fluid. A thermodynamic model of the cycle was developed by applying the law of conservation of mass and the First Law of Thermodynamics. The model was implemented and solved using the EES software. Operational temperatures of condenser, evaporator, generator and absorber, were varied. The thermodynamic analysis showed that the coefficient of performance (COP) of the cycle was higher for higher evaporation temperatures, lower condensing temperatures and lower absorber outlet temperatures. Considering all the simulations performed, the COP values were between 0.63 and 0.84, with the evaporation temperature being the most influential parameter of the cycle. It was observed that higher condensing temperatures require higher minimum temperatures in generator 2 due to heat transfers limitations that occur internally in the cycle. The influence of each stage of the cycle on the generation of refrigerant vapor varied with the cycle operating parameters, with the first stage being responsible for approximately 70 % of the mass flow generated.

International Journal of ThermofluidsVol. 27
Universidade Federal do Rio Grande do Sul (BR), GLA University (IN)
Openalex Percentile: Top 10%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
2.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Double effect and double stage absorption refrigeration cycle thermodynamic study — William Galiotto, Andrés Z. Mendiburu, et al. · International Journal of Thermofluids (2025) | TGRS Research Map | TGRS