Reproducibility of the Determination of <sup>13</sup>C‐Labeling of Glutamate and Glutamine in the Human Brain Using selPOCE‐MRS at 7 T Upon [U‐<sup>13</sup>C]–Labeled Glucose Infusion

Glutamate (Glu) is the major excitatory neurotransmitter in the central nervous system. The measurement of Glu/glutamine (Gln) neurotransmitters in the brain provides valuable insights into the dynamic aspects of neuroenergetics and neurotransmitter cycles and can be accomplished through the detection of <sup>13</sup>C-labeling of Glu and Gln during the administration of <sup>13</sup>C-labeled glucose. Our goal is to evaluate the reproducibility of selective proton-observed, carbon-edited (selPOCE) MRS at 7 T for the detection of <sup>13</sup>C-labeled Glu and Gln in the human brain. Data of three healthy participants, who were scanned twice at 7 T while undergoing [U-<sup>13</sup>C]-glucose infusion for 120 min, were used to detect <sup>13</sup>C-labeled Glu and Gln in the brain, using selPOCE-STEAM-MRS. There was a rapid increase of plasma glucose <sup>13</sup>C fractional enrichment (FE) during the first 20 min of infusion, followed by a steady state of plasma glucose <sup>13</sup>C FE until the end of the [U-<sup>13</sup>C]-glucose infusion. The time courses of <sup>13</sup>C-labeling of Glu and Gln were similar for test/retest. The test/retest variability was 15.8% for <sup>13</sup>C-Glu and 33.3% for <sup>13</sup>C-Gln. Knowing the variability of these readings using selPOCE-STEAM-MRS can inform the application to future studies on disease-specific alterations in Glu/Gln cycling.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-04-09
DOI
https://doi.org/10.1002/nbm.70026
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducibility of the Determination of 13C‐Labeling of Glutamate and Glutamine in the Human Brain Using selPOCE‐MRS at 7 T Upon [U‐13C]–Labeled Glucose Infusion

Chantal Mahon, Dennis W. J. Klomp, Jeanine J. Prompers, Mark Gosselink et al.
1 citations
NMR in Biomedicine
Advanced MRI Techniques and Applications
1.36
article

Reproducibility of the Determination of 13C‐Labeling of Glutamate and Glutamine in the Human Brain Using selPOCE‐MRS at 7 T Upon [U‐13C]–Labeled Glucose Infusion

Chantal Mahon, Dennis W. J. Klomp, Jeanine J. Prompers, Mark Gosselink, Anastasia Coppoli, Pieter van Eijsden, Anthony S. Basile, Evita Wiegers, Robin A. de Graaf, Graeme F. Mason, Hans Hoogduin, Corin O. Miller, Wybe J. M. van der Kemp, Sarah Jacobs, Narjes Ahmadian, Dirk Cerneus, Helia Norouzizadeh, Inge De Lepeleire, Renger Tiessen
article en
1 citations

Abstract

Glutamate (Glu) is the major excitatory neurotransmitter in the central nervous system. The measurement of Glu/glutamine (Gln) neurotransmitters in the brain provides valuable insights into the dynamic aspects of neuroenergetics and neurotransmitter cycles and can be accomplished through the detection of <sup>13</sup>C-labeling of Glu and Gln during the administration of <sup>13</sup>C-labeled glucose. Our goal is to evaluate the reproducibility of selective proton-observed, carbon-edited (selPOCE) MRS at 7 T for the detection of <sup>13</sup>C-labeled Glu and Gln in the human brain. Data of three healthy participants, who were scanned twice at 7 T while undergoing [U-<sup>13</sup>C]-glucose infusion for 120 min, were used to detect <sup>13</sup>C-labeled Glu and Gln in the brain, using selPOCE-STEAM-MRS. There was a rapid increase of plasma glucose <sup>13</sup>C fractional enrichment (FE) during the first 20 min of infusion, followed by a steady state of plasma glucose <sup>13</sup>C FE until the end of the [U-<sup>13</sup>C]-glucose infusion. The time courses of <sup>13</sup>C-labeling of Glu and Gln were similar for test/retest. The test/retest variability was 15.8% for <sup>13</sup>C-Glu and 33.3% for <sup>13</sup>C-Gln. Knowing the variability of these readings using selPOCE-STEAM-MRS can inform the application to future studies on disease-specific alterations in Glu/Gln cycling.

NMR in BiomedicineVol. 38(5)
Merck & Co., Inc., Rahway, NJ, USA (United States) (US), University Medical Center Utrecht (NL), Yale University (US), MSD (Belgium) (BE)
Openalex Percentile: Top 22%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.