Investigation of total-body applicable compartment models for kinetic modeling in total body $$^{15}$$O-water perfusion PET imaging

Abstract Dynamic total-body positron emission tomography (PET) imaging has recently become possible due to the introduction of new-generation imaging systems with increased axial field of view. This enables evaluation of kinetic modeling approaches using compartment models for the entire body simultaneously. Systematic evaluation of the conventionally used approaches is needed to find the best candidates among different compartment models for total body modeling of $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water perfusion PET images. Six variations of the 1-tissue-compartment model (1TCM) are evaluated. The models are systematically fitted to mean time activity curves of 20 anatomic structures of interest extracted from a dynamic $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water PET rest perfusion images of 58 human subjects, using an image-derived input function from the aorta. The impact of additional parameters for time delay correction (TDC), arterial volume fraction (AVF), and perfusable tissue fraction (PTF) is assessed. The models are evaluated with mean squared error, mean relative error (MRE), and Akaike information criterion (AIC) and by performing Wilcoxon signed-rank tests to see whether the found differences are statistically significant. For 11 out of the 20 anatomic structures, the best model in terms of median AIC was the 1TCM with AVF and TDC but without PTF. The use of TDC resulted in significantly lower AICs for all anatomic structures while the AVF and PTF parameters significantly improved the model performance only occasionally. Between the different organs, the models of pancreas, spleen, myocardium, the example rib, and brain performed very well in terms of MRE. In comparison, the investigated models worked poorly for liver and lung lobes. This paper serves as an initial attempt to evaluate potential approaches to derive an appropriate model for kinetic modeling in total body $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water PET perfusion imaging. According to our research, the suitability of 1TCM using a single input function from the aorta in $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water PET images depends on the organ of interest. Our results suggest that the use of 1TCM is justified for most anatomic structures and can be used to estimate the cerebral, myocardial, renal, and splenic blood flow. However, we recommend different models for quantification of hepatic and pulmonary blood flow.

Authors

Institutions

Publication Details

Journal
Network Modeling Analysis in Health Informatics and Bioinformatics
Published
2025-04-09
DOI
https://doi.org/10.1007/s13721-025-00515-3
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of total-body applicable compartment models for kinetic modeling in total body $$^{15}$$O-water perfusion PET imaging

Oona Rainio, Riku Klén, Juhani Knuuti
2 citations
Network Modeling Analysis in Health Informatics and Bioinformatics
Medical Imaging Techniques and Applications
2.72
article

Investigation of total-body applicable compartment models for kinetic modeling in total body $$^{15}$$O-water perfusion PET imaging

Oona Rainio, Riku Klén, Juhani Knuuti
article en
2 citations

Abstract

Abstract Dynamic total-body positron emission tomography (PET) imaging has recently become possible due to the introduction of new-generation imaging systems with increased axial field of view. This enables evaluation of kinetic modeling approaches using compartment models for the entire body simultaneously. Systematic evaluation of the conventionally used approaches is needed to find the best candidates among different compartment models for total body modeling of $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water perfusion PET images. Six variations of the 1-tissue-compartment model (1TCM) are evaluated. The models are systematically fitted to mean time activity curves of 20 anatomic structures of interest extracted from a dynamic $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water PET rest perfusion images of 58 human subjects, using an image-derived input function from the aorta. The impact of additional parameters for time delay correction (TDC), arterial volume fraction (AVF), and perfusable tissue fraction (PTF) is assessed. The models are evaluated with mean squared error, mean relative error (MRE), and Akaike information criterion (AIC) and by performing Wilcoxon signed-rank tests to see whether the found differences are statistically significant. For 11 out of the 20 anatomic structures, the best model in terms of median AIC was the 1TCM with AVF and TDC but without PTF. The use of TDC resulted in significantly lower AICs for all anatomic structures while the AVF and PTF parameters significantly improved the model performance only occasionally. Between the different organs, the models of pancreas, spleen, myocardium, the example rib, and brain performed very well in terms of MRE. In comparison, the investigated models worked poorly for liver and lung lobes. This paper serves as an initial attempt to evaluate potential approaches to derive an appropriate model for kinetic modeling in total body $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water PET perfusion imaging. According to our research, the suitability of 1TCM using a single input function from the aorta in $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water PET images depends on the organ of interest. Our results suggest that the use of 1TCM is justified for most anatomic structures and can be used to estimate the cerebral, myocardial, renal, and splenic blood flow. However, we recommend different models for quantification of hepatic and pulmonary blood flow.

Network Modeling Analysis in Health Informatics and BioinformaticsVol. 14(1)
University of Turku (FI), Turku University Hospital (FI), Turku PET Centre (FI)
Suomen Kulttuurirahasto, Turun Yliopisto
Openalex Percentile: Top 11%
Medical Imaging Techniques and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.