Electrochemical microfluidic biosensor for the detection of CD4+ T cells

Since the onset of the HIV epidemic, assessing CD4<sup>+</sup> T-cells has become a routine procedure for evaluating immune deficiency, with flow cytometry established as the gold standard. Over time, various strategies and platforms have been introduced to improve CD4<sup>+</sup> cell enumeration, aiming to enhance the performance of diagnostic devices and bring the service closer to patients. These advancements are particularly critical for low-resource settings and point-of-care applications, where the excellent performance of flow cytometry is hindered by its unsuitability in such environments. This work presents an innovative electrochemical microfluidic device that, with further development, could be applied for HIV management in low resource settings. The setup integrates an electrochemical sensor within a PDMS microfluidic structure, allowing for on-chip electrode functionalization and cell detection. Using electrochemical impedance spectroscopy, the biosensor demonstrates a linear detection range from 1.25 × 10<sup>5</sup> to 2 × 10<sup>6</sup> cells/mL, with a detection limit of 1.41 × 10<sup>5</sup> cells/mL for CD4<sup>+</sup> cells isolated from blood samples, aligning with clinical ranges for both healthy and HIV<sup>+</sup> patients. The biosensor shows specificity towards CD4<sup>+</sup> cells with negligible response to monocytes, neutrophils, and bovine serum albumin. Its integration with a microfluidic chip for sensor fabrication and cell detection, compact size, minimal manual handling, ease of fabrication, electrochemical detection capability, and potential for multiplexing together with the detection range make the device particularly advantageous for use in low-resource settings, standing out among other devices described in the literature. This study also investigates the integration of a microfluidic Dean Flow Fractionation (DFF) chip for cell separation.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2025-04-09
DOI
https://doi.org/10.1038/s41378-025-00893-8
Citations
5
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
4.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical microfluidic biosensor for the detection of CD4+ T cells

Scott Ward, Razieh Salimian, Chayakorn Petchakup, Mark A. Lindsay et al.
5 citations
Microsystems & Nanoengineering
Advanced biosensing and bioanalysis techniques
4.03
article

Electrochemical microfluidic biosensor for the detection of CD4+ T cells

Scott Ward, Razieh Salimian, Chayakorn Petchakup, Mark A. Lindsay, Han Wei Hou, Katarzyna Białas, Pedro Estrela, Hui Min Tay
article en
5 citations

Abstract

Since the onset of the HIV epidemic, assessing CD4<sup>+</sup> T-cells has become a routine procedure for evaluating immune deficiency, with flow cytometry established as the gold standard. Over time, various strategies and platforms have been introduced to improve CD4<sup>+</sup> cell enumeration, aiming to enhance the performance of diagnostic devices and bring the service closer to patients. These advancements are particularly critical for low-resource settings and point-of-care applications, where the excellent performance of flow cytometry is hindered by its unsuitability in such environments. This work presents an innovative electrochemical microfluidic device that, with further development, could be applied for HIV management in low resource settings. The setup integrates an electrochemical sensor within a PDMS microfluidic structure, allowing for on-chip electrode functionalization and cell detection. Using electrochemical impedance spectroscopy, the biosensor demonstrates a linear detection range from 1.25 × 10<sup>5</sup> to 2 × 10<sup>6</sup> cells/mL, with a detection limit of 1.41 × 10<sup>5</sup> cells/mL for CD4<sup>+</sup> cells isolated from blood samples, aligning with clinical ranges for both healthy and HIV<sup>+</sup> patients. The biosensor shows specificity towards CD4<sup>+</sup> cells with negligible response to monocytes, neutrophils, and bovine serum albumin. Its integration with a microfluidic chip for sensor fabrication and cell detection, compact size, minimal manual handling, ease of fabrication, electrochemical detection capability, and potential for multiplexing together with the detection range make the device particularly advantageous for use in low-resource settings, standing out among other devices described in the literature. This study also investigates the integration of a microfluidic Dean Flow Fractionation (DFF) chip for cell separation.

Microsystems & NanoengineeringVol. 11(1)
Nanyang Technological University (SG), University of Bath (GB)
University of Bath, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 7%
Advanced biosensing and bioanalysis techniques
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.