Development of a 3-D tomography technique for Large Helical Device bolometry using EMC3-EIRENE grids

A three-dimensional (3-D) tomography technique is developed for the bolometry system in the Large Helical Device using the EMC3-EIRENE-defined mesh coordinates and the relative gradient smoothing extended to 3-D space. We utilize two types of bolometers, resistive bolometers and infra-red imaging video bolometers, to cover areas that are not visible with only one type of bolometer, the total channels of which are 1088. Although the resolution of the reconstructed solution rises to 59 400 voxels, we prove that the physically meaningful solution having little negative power is obtained by calculating geometry matrices with the tetrahedralization method and assessing the phantom emission and the synthetic data. Moreover, comparing solutions generated by conventional minimum Fisher regularization and 3-D extended relative gradient smoothing enables us to find that the latter provides a better solution.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-04-01
DOI
https://doi.org/10.1063/5.0225703
Citations
1
Primary Topic
Numerical methods in inverse problems
Type
article
Field-Weighted Citation Impact
3.69

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a 3-D tomography technique for Large Helical Device bolometry using EMC3-EIRENE grids

D. Zhang, G. Kawamura, F. Reimold, Koyo Munechika et al.
1 citations
Review of Scientific Instruments
Numerical methods in inverse problems
3.69
article

Development of a 3-D tomography technique for Large Helical Device bolometry using EMC3-EIRENE grids

D. Zhang, G. Kawamura, F. Reimold, Koyo Munechika, Hiroaki Tsutsui, K. Mukai, G. Partesotti, Byron J. Peterson
article en
1 citations

Abstract

A three-dimensional (3-D) tomography technique is developed for the bolometry system in the Large Helical Device using the EMC3-EIRENE-defined mesh coordinates and the relative gradient smoothing extended to 3-D space. We utilize two types of bolometers, resistive bolometers and infra-red imaging video bolometers, to cover areas that are not visible with only one type of bolometer, the total channels of which are 1088. Although the resolution of the reconstructed solution rises to 59 400 voxels, we prove that the physically meaningful solution having little negative power is obtained by calculating geometry matrices with the tetrahedralization method and assessing the phantom emission and the synthetic data. Moreover, comparing solutions generated by conventional minimum Fisher regularization and 3-D extended relative gradient smoothing enables us to find that the latter provides a better solution.

Review of Scientific InstrumentsVol. 96(4)
Tokyo Institute of Technology (JP), The Graduate University for Advanced Studies, SOKENDAI (JP), National Institute for Fusion Science (JP), National Institutes for Quantum Science and Technology (JP), Max Planck Institute for Plasma Physics - Greifswald (DE)
Deutscher Akademischer Austauschdienst, Japan Society for the Promotion of Science, National Institutes of Natural Sciences
Life below water
Openalex Percentile: Top 12%
Numerical methods in inverse problems
3.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a 3-D tomography technique for Large Helical Device bolometry using EMC3-EIRENE grids — D. Zhang, G. Kawamura, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS