Serum visfatin characteristic peak screening coronary heart disease study based on Raman spectroscopy

This study used Raman spectroscopy to explore differences between serum visfatin and its subcomponents in healthy people and coronary heart disease (CHD) patients. To explore whether serum visfatin can be used as screening biomarker for CDH. In total, 60 CHD patients and 57 healthy people were enrolled from Xinjiang Production and Construction Corps Seventh Division Hospital. Serum samples were collected and detected by Raman spectroscopy, and the characteristic peaks of serum visfatin were analyzed. The spectral peaks analysis showed, the peaks at 850.95, 1265.92, 1336.99, 1446.48, 1603.83, and 1657.69 cm-1 were stronger in the CHD patient sample, and the spectral peaks at 1000.52, 1154.51, and 1515.53 cm-1 were stronger in the healthy sample. Clinical sample verification revealed that the 1265.92 and 1446.48 cm-1 peaks had certain distinguishing effects on CHD patients and healthy people.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2025-04-04
DOI
https://doi.org/10.1097/md.0000000000042081
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Serum visfatin characteristic peak screening coronary heart disease study based on Raman spectroscopy

Xiayan Liu, Yang Zhong-wei, Lv Chaohui, Feng Shi et al.
Medicine
Spectroscopy Techniques in Biomedical and Chemical Research
article

Serum visfatin characteristic peak screening coronary heart disease study based on Raman spectroscopy

Xiayan Liu, Yang Zhong-wei, Lv Chaohui, Feng Shi, Lujia Yang
article en

Abstract

This study used Raman spectroscopy to explore differences between serum visfatin and its subcomponents in healthy people and coronary heart disease (CHD) patients. To explore whether serum visfatin can be used as screening biomarker for CDH. In total, 60 CHD patients and 57 healthy people were enrolled from Xinjiang Production and Construction Corps Seventh Division Hospital. Serum samples were collected and detected by Raman spectroscopy, and the characteristic peaks of serum visfatin were analyzed. The spectral peaks analysis showed, the peaks at 850.95, 1265.92, 1336.99, 1446.48, 1603.83, and 1657.69 cm-1 were stronger in the CHD patient sample, and the spectral peaks at 1000.52, 1154.51, and 1515.53 cm-1 were stronger in the healthy sample. Clinical sample verification revealed that the 1265.92 and 1446.48 cm-1 peaks had certain distinguishing effects on CHD patients and healthy people.

MedicineVol. 104(14)
Shihezi University (CN), Xinjiang Production and Construction Corps (CN), Maternal and Child Health Hospital of Xinjiang Uygur Autonomous Region (CN), Shaanxi Provincial People's Hospital (CN)
Openalex Percentile: Top 94%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.