Comment on an unidentifiably severed LMA supreme: An unanticipated critical incident

Dear Editor, I read with great interest the publication “An unidentifiably severed laryngeal mask airway (LMA) supreme: An unanticipated critical incident” by Pruthi G et al.[1] Only a few studies have documented such unique breakage, and all have denied any undue pressure from the patient circuit on the LMA.[2,3] I would like to contribute that none of the studies mentioned the dates of manufacturing and expiry. LMAs have a long shelf life, and many LMAs, such as the LMA® ProSeal™, are reused without any breakage or leaks. The LMA supreme, made of polyvinyl chloride, has a shelf life of 5 years and can only be used within a temperature range of −10 to +60°C. High temperatures and low humidity can lead to yellowing and degradation of the LMA. All types of plastic polymers have a degradation (thermo-oxidative) rate that should also be taken into account.[4] Second, the pressure applied during manipulation of the fixation tab should also be considered, but nothing concrete has been documented. Last, in packaging, only the airway cuff is enclosed in a protective hard casing, whereas the entire LMA is covered by a thin paper-plastic cover, which does not provide adequate protection for the rest of the LMA. All components should be thoroughly checked before use. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.

Authors

Institutions

Publication Details

Journal
Journal of Anaesthesiology Clinical Pharmacology
Published
2025-04-09
DOI
https://doi.org/10.4103/joacp.joacp_438_24
Primary Topic
Renal function and acid-base balance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comment on an unidentifiably severed LMA supreme: An unanticipated critical incident

Ravneet Kaur Gill
Journal of Anaesthesiology Clinical Pharmacology
Renal function and acid-base balance
article

Comment on an unidentifiably severed LMA supreme: An unanticipated critical incident

Ravneet Kaur Gill
article en

Abstract

Dear Editor, I read with great interest the publication “An unidentifiably severed laryngeal mask airway (LMA) supreme: An unanticipated critical incident” by Pruthi G et al.[1] Only a few studies have documented such unique breakage, and all have denied any undue pressure from the patient circuit on the LMA.[2,3] I would like to contribute that none of the studies mentioned the dates of manufacturing and expiry. LMAs have a long shelf life, and many LMAs, such as the LMA® ProSeal™, are reused without any breakage or leaks. The LMA supreme, made of polyvinyl chloride, has a shelf life of 5 years and can only be used within a temperature range of −10 to +60°C. High temperatures and low humidity can lead to yellowing and degradation of the LMA. All types of plastic polymers have a degradation (thermo-oxidative) rate that should also be taken into account.[4] Second, the pressure applied during manipulation of the fixation tab should also be considered, but nothing concrete has been documented. Last, in packaging, only the airway cuff is enclosed in a protective hard casing, whereas the entire LMA is covered by a thin paper-plastic cover, which does not provide adequate protection for the rest of the LMA. All components should be thoroughly checked before use. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.

Journal of Anaesthesiology Clinical PharmacologyVol. 41(3)
Ambedkar University Delhi (IN), Institute of Medical Sciences (IN)
Gender equality
Openalex Percentile: Top 91%
Renal function and acid-base balance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comment on an unidentifiably severed LMA supreme: An unanticipated critical incident — Ravneet Kaur Gill · Journal of Anaesthesiology Clinical Pharmacology (2025) | TGRS Research Map | TGRS