Fluorescent Cell Barcoding of Peripheral Blood Mononuclear Cells for High‐Throughput Assessment of Vaccine‐Induced T Cell Responses in Low‐Volume Research Samples

T cell responses are rarely measured in large-scale human vaccine studies due to the sample volumes required, as well as the logistical, technical, and financial challenges associated with available assays. Fluorescent cell barcoding has been proposed in other contexts to allow for more high-throughput flow cytometry-based assays. Here, we aimed to expand on existing barcoding approaches to develop a reagent and sample-sparing assay for in-depth assessment of T cell responses to vaccine antigens. By using various concentrations of two fixable viability dyes in a matrix format, up to 25 samples that were pooled and acquired together could be successfully deconvoluted based on their unique fluorescent signature. This fluorescent cell barcoding approach was then combined with extracellular and intracellular staining to identify functional (i.e., producing at least one cytokine) and polyfunctional (i.e., producing multiple cytokines) T cells in response to vaccine antigen stimulation. As a proof-of-concept, we plated just 200,000 peripheral blood mononuclear cells (PBMC) per condition, and by staining and acquiring only two pooled samples, we were able to detect rare antigen-specific T cell responses in eight donors to four stimulants each. The frequencies of antigen-induced cytokine-positive cells detected in barcoded samples with 200,000 input PBMC were strongly correlated with those detected in non-barcoded samples from the same donors with 1 million input PBMC, demonstrating the validity of this approach. In conclusion, by reducing the number of PBMC needed by five-fold, and the volume of staining reagents needed by 25-fold, this assay has widespread potential applications to human vaccine studies.

Authors

Institutions

Publication Details

Journal
Cytometry Part A
Published
2025-04-09
DOI
https://doi.org/10.1002/cyto.a.24933
Primary Topic
T-cell and B-cell Immunology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fluorescent Cell Barcoding of Peripheral Blood Mononuclear Cells for High‐Throughput Assessment of Vaccine‐Induced T Cell Responses in Low‐Volume Research Samples

Nathalie Simard, Tania H. Watts, Shelly Bolotin, Janna R. Shapiro
Cytometry Part A
T-cell and B-cell Immunology
article

Fluorescent Cell Barcoding of Peripheral Blood Mononuclear Cells for High‐Throughput Assessment of Vaccine‐Induced T Cell Responses in Low‐Volume Research Samples

Nathalie Simard, Tania H. Watts, Shelly Bolotin, Janna R. Shapiro
article en

Abstract

T cell responses are rarely measured in large-scale human vaccine studies due to the sample volumes required, as well as the logistical, technical, and financial challenges associated with available assays. Fluorescent cell barcoding has been proposed in other contexts to allow for more high-throughput flow cytometry-based assays. Here, we aimed to expand on existing barcoding approaches to develop a reagent and sample-sparing assay for in-depth assessment of T cell responses to vaccine antigens. By using various concentrations of two fixable viability dyes in a matrix format, up to 25 samples that were pooled and acquired together could be successfully deconvoluted based on their unique fluorescent signature. This fluorescent cell barcoding approach was then combined with extracellular and intracellular staining to identify functional (i.e., producing at least one cytokine) and polyfunctional (i.e., producing multiple cytokines) T cells in response to vaccine antigen stimulation. As a proof-of-concept, we plated just 200,000 peripheral blood mononuclear cells (PBMC) per condition, and by staining and acquiring only two pooled samples, we were able to detect rare antigen-specific T cell responses in eight donors to four stimulants each. The frequencies of antigen-induced cytokine-positive cells detected in barcoded samples with 200,000 input PBMC were strongly correlated with those detected in non-barcoded samples from the same donors with 1 million input PBMC, demonstrating the validity of this approach. In conclusion, by reducing the number of PBMC needed by five-fold, and the volume of staining reagents needed by 25-fold, this assay has widespread potential applications to human vaccine studies.

Cytometry Part AVol. 107(5)
University of Toronto (CA), Public Health Ontario (CA)
Canadian Immunization Research Network, Canadian Institutes of Health Research
Openalex Percentile: Top 92%
T-cell and B-cell Immunology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.