Neutral Position or Contralateral Head Rotation in Vagus Nerve Stimulation Surgery: A Study of Surgical Pathway and Nervus Vagus Position with Peroperative Ultrasonography

<i>Background and Objectives</i>: This study aimed to discuss positional changes in the sternocleidomastoid (SCM) muscle and vagus nerve with head position, their effect on the surgical path, positional variations, the selection of an appropriate position for surgery, their effects on the surgical procedure, and complications by using peroperative ultrasonography. <i>Materials and Methods</i>: Vagal nerve stimulation surgery patients over the age of 18 years were included. Peroperative ultrasonography images were scanned, and changes in head position and anatomical and positional variations in the SCM muscle and vagus nerve at the surgical incision level were examined. <i>Results</i>: SCM localization was most frequently observed in the lateral aspect of the carotid sheath (n:16) in neutral position, while it was mostly observed in the medial aspect of the carotid sheath (n:16) at a 15 degree rotation. The vagus nerve was mostly observed between the jugular vein and carotid artery in neutral position (n:21), and it was observed at the same position at a 15 degree rotation (n:17). The positional change of the SCM muscle with head position was found to be statistically significant (<i>p</i> < 0.001), while the positional change of the vagus nerve was not (<i>p</i>:0.198). <i>Conclusions:</i> The SCM muscle closes the surgical path with head rotation by either deviating over the carotid sheath or increasing its deviation. In addition to its anatomical variations, the vagus nerve shows different positional changes with head rotation. Deciding on the head position in vagal nerve stimulation surgery, using peroperative ultrasonography rather than a routine position, may be effective in reducing surgical time and possible complications.

Authors

Institutions

Publication Details

Journal
Brain Sciences
Published
2025-04-08
DOI
https://doi.org/10.3390/brainsci15040385
Primary Topic
Vagus Nerve Stimulation Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Neutral Position or Contralateral Head Rotation in Vagus Nerve Stimulation Surgery: A Study of Surgical Pathway and Nervus Vagus Position with Peroperative Ultrasonography

Güven Gürsoy, Gönül Güvenç
1 links
Brain Sciences
Vagus Nerve Stimulation Research
article

Neutral Position or Contralateral Head Rotation in Vagus Nerve Stimulation Surgery: A Study of Surgical Pathway and Nervus Vagus Position with Peroperative Ultrasonography

Güven Gürsoy, Gönül Güvenç
article en

Abstract

<i>Background and Objectives</i>: This study aimed to discuss positional changes in the sternocleidomastoid (SCM) muscle and vagus nerve with head position, their effect on the surgical path, positional variations, the selection of an appropriate position for surgery, their effects on the surgical procedure, and complications by using peroperative ultrasonography. <i>Materials and Methods</i>: Vagal nerve stimulation surgery patients over the age of 18 years were included. Peroperative ultrasonography images were scanned, and changes in head position and anatomical and positional variations in the SCM muscle and vagus nerve at the surgical incision level were examined. <i>Results</i>: SCM localization was most frequently observed in the lateral aspect of the carotid sheath (n:16) in neutral position, while it was mostly observed in the medial aspect of the carotid sheath (n:16) at a 15 degree rotation. The vagus nerve was mostly observed between the jugular vein and carotid artery in neutral position (n:21), and it was observed at the same position at a 15 degree rotation (n:17). The positional change of the SCM muscle with head position was found to be statistically significant (<i>p</i> < 0.001), while the positional change of the vagus nerve was not (<i>p</i>:0.198). <i>Conclusions:</i> The SCM muscle closes the surgical path with head rotation by either deviating over the carotid sheath or increasing its deviation. In addition to its anatomical variations, the vagus nerve shows different positional changes with head rotation. Deciding on the head position in vagal nerve stimulation surgery, using peroperative ultrasonography rather than a routine position, may be effective in reducing surgical time and possible complications.

Brain SciencesVol. 15(4)
Muğla University (TR)
Openalex Percentile: Top 90%
Vagus Nerve Stimulation Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Neutral Position or Contralateral Head Rotation in Vagus Nerve Stimulation Surgery: A Study of Surgical Pathway and Nervus Vagus Position with Peroperative Ultrasonography — Güven Gürsoy, Gönül Güvenç · Brain Sciences (2025) | TGRS Research Map | TGRS