Assessment of patient entrance surface and effective dose in the skull and thoraco-lumbar X-ray examinations

<b>Purpose:</b> The review effort throughout the states was needed by the major concern of increased risk of cancer due to radiation exposure in patients during routine X-ray. This study aims to assess the patient entrance surface dosage during X-ray examinations of the skull and thoraco-lumbar spine.<br /> <b>Materials and methods: </b>Using a CALDOSE software tool, the dosage received by 146 individuals was assessed based on many technical criteria, including the source-to-image receptor distance, photon quantity by mill ampere second, and photon energy by kilo volt peak.<br /> <b>Results:</b> The average entrance surface air kerma (ESAK) is 0.52 for the skull and 0.77 for the thoracic spine. The typical value of the incident air kerma (INAK) is 0.47 for the skull and 0.58 for the thoracic lumbar region.<br /> <b>Conclusions:</b> ESAK and INAK are quite effective for comparing the thoracic spine to the cranium. ESAK and INAK can offer data on dosage reduction that should be utilized in the optimization of skull and thoraco-lumbar X-ray examinations.

Authors

Institutions

Publication Details

Journal
Electronic Journal of General Medicine
Published
2025-04-09
DOI
https://doi.org/10.29333/ejgm/16262
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of patient entrance surface and effective dose in the skull and thoraco-lumbar X-ray examinations

Mohannad Adel Sayah, Ahmed Abukonna, Mohammed A. Hussein, Marwan Alshipli et al.
Electronic Journal of General Medicine
Radiation Dose and Imaging
article

Assessment of patient entrance surface and effective dose in the skull and thoraco-lumbar X-ray examinations

Mohannad Adel Sayah, Ahmed Abukonna, Mohammed A. Hussein, Marwan Alshipli, Ibrahim G. Abdelrhman
article en

Abstract

<b>Purpose:</b> The review effort throughout the states was needed by the major concern of increased risk of cancer due to radiation exposure in patients during routine X-ray. This study aims to assess the patient entrance surface dosage during X-ray examinations of the skull and thoraco-lumbar spine.<br /> <b>Materials and methods: </b>Using a CALDOSE software tool, the dosage received by 146 individuals was assessed based on many technical criteria, including the source-to-image receptor distance, photon quantity by mill ampere second, and photon energy by kilo volt peak.<br /> <b>Results:</b> The average entrance surface air kerma (ESAK) is 0.52 for the skull and 0.77 for the thoracic spine. The typical value of the incident air kerma (INAK) is 0.47 for the skull and 0.58 for the thoracic lumbar region.<br /> <b>Conclusions:</b> ESAK and INAK are quite effective for comparing the thoracic spine to the cranium. ESAK and INAK can offer data on dosage reduction that should be utilized in the optimization of skull and thoraco-lumbar X-ray examinations.

Electronic Journal of General MedicineVol. 22(3)
Al-Hussein Bin Talal University (JO), October 6 University (EG), Sudan University of Science and Technology (SD)
Openalex Percentile: Top 89%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of patient entrance surface and effective dose in the skull and thoraco-lumbar X-ray examinations — Mohannad Adel Sayah, Ahmed Abukonna, et al. · Electronic Journal of General Medicine (2025) | TGRS Research Map | TGRS