An artificial intelligence model for predicting an appropriate mAs with target exposure indicator for chest digital radiography

In digital radiography, image quality is synergistically affected by anatomy-specific examinations, exposure factors, body parameters, detector types, and vendors/systems. However, estimating appropriate exposure factors before radiography with optimized image quality without overexposure or underexposure to patients is difficult. Thus, there is an unmet need to establish a model to predict appropriate mAs for optimizing image quality before radiography. This study aimed to establish a machine learning (ML) model for predicting an appropriate current-time product (mAs) using the target exposure indicator in chest digital radiography. An anthropomorphic chest phantom was used to establish a target exposure indicator which was used to define overexposure and underexposure in the human study. This study enrolled 1,000 (M/F = 915/85) subjects who underwent regular chest radiography. The chest thickness, height, weight, body mass index, mAs, and concomitant reached exposure (REX) were recorded. To construct the prediction model, the dataset was randomly separated into training (80%) and testing (20%) sets by matching their demographic characteristics. Five ML models were trained using the training set with 10-fold cross validation, and the model performance was evaluated using the testing set with correlation coefficients, root-mean-square error, and mean average error. The phantom study showed that the average REX was 355.6 which served as the target exposure indicator. In human study, the comparisons showed that the artificial neural network (ANN) model was the most suitable for predicting both REX and mAs values. The results demonstrated that, on average, the predicted mAs values were 10% lower and 8% higher than the values determined by AEC in the overexposure (REX > 355.6) and underexposure (REX < 355.6) groups, respectively. Moreover, the predicted mAs values were further reduced in all patients when lowering the target REX values. We concluded that the ML approach was feasible for building an artificial intelligence model for predicting appropriate mAs with target exposure indicator for chest digital radiography.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-08
DOI
https://doi.org/10.1038/s41598-025-96947-y
Citations
1
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
1.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An artificial intelligence model for predicting an appropriate mAs with target exposure indicator for chest digital radiography

Ming‐Chung Chou, Jiaru Lin, Tai-Yuan Chen, Yu-Syuan Liang et al.
1 citations
Scientific Reports
Digital Radiography and Breast Imaging
1.52
article

An artificial intelligence model for predicting an appropriate mAs with target exposure indicator for chest digital radiography

Ming‐Chung Chou, Jiaru Lin, Tai-Yuan Chen, Yu-Syuan Liang, Jyun-Jie Li
article en
1 citations

Abstract

In digital radiography, image quality is synergistically affected by anatomy-specific examinations, exposure factors, body parameters, detector types, and vendors/systems. However, estimating appropriate exposure factors before radiography with optimized image quality without overexposure or underexposure to patients is difficult. Thus, there is an unmet need to establish a model to predict appropriate mAs for optimizing image quality before radiography. This study aimed to establish a machine learning (ML) model for predicting an appropriate current-time product (mAs) using the target exposure indicator in chest digital radiography. An anthropomorphic chest phantom was used to establish a target exposure indicator which was used to define overexposure and underexposure in the human study. This study enrolled 1,000 (M/F = 915/85) subjects who underwent regular chest radiography. The chest thickness, height, weight, body mass index, mAs, and concomitant reached exposure (REX) were recorded. To construct the prediction model, the dataset was randomly separated into training (80%) and testing (20%) sets by matching their demographic characteristics. Five ML models were trained using the training set with 10-fold cross validation, and the model performance was evaluated using the testing set with correlation coefficients, root-mean-square error, and mean average error. The phantom study showed that the average REX was 355.6 which served as the target exposure indicator. In human study, the comparisons showed that the artificial neural network (ANN) model was the most suitable for predicting both REX and mAs values. The results demonstrated that, on average, the predicted mAs values were 10% lower and 8% higher than the values determined by AEC in the overexposure (REX > 355.6) and underexposure (REX < 355.6) groups, respectively. Moreover, the predicted mAs values were further reduced in all patients when lowering the target REX values. We concluded that the ML approach was feasible for building an artificial intelligence model for predicting appropriate mAs with target exposure indicator for chest digital radiography.

Scientific ReportsVol. 15(1)
E-Da Hospital (TW), Kaohsiung Armed Forces General Hospital (TW), Chi Mei Medical Center (TW), Chang Jung Christian University (TW)
Ministry of Science and Technology, Taiwan, Kaohsiung Armed Forces General Hospital
Openalex Percentile: Top 20%
Digital Radiography and Breast Imaging
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.