New RP-HPLC Method for Bilastine Estimation in Pharmaceutical and Bulk Dose Form

Bilastine is a frequently prescribed H1-antihistaminic that is authorized for the safe and efficient symptomatic management of allergic conditions, such as urticaria and rhino conjunctivitis. For the quick and precise measurement of bilastine, an Agilent Technologies LC compact 1120 module, a Shimadzu UV-1700 detector with a 20µl injection volume, and an xBridge TM C18 column were used in developing the validated Reverse Phase HPLC method. The procedure used a mobile phase made up of a 60:40, v/v% combination of methanol, 10 mM potassium dihydrogen phosphate at pH 3.5. By using the working standard solution, 10 µg/ml, satisfactory linearity shown over 5–30 µg/ml concentration range (correlation coefficient: 0.9924). Detection was done at 275 nm with a five-minute reaction time and the flow rate was maintained at 1.0 ml/min. The precision, accuracy, linearity, and robustness of the approach were confirmed by statistical validation in compliance with ICH criteria. This implies that the method for figuring out the tablet formulations is suitable. DOI: https://doi.org/10.52783/jchr.v15.i2.7707

Publication Details

Journal
Journal of chemical health risks
Published
2025-01-01
DOI
https://doi.org/10.52783/jchr.v15.i2.7707
Primary Topic
Chemical and Physical Properties in Aqueous Solutions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New RP-HPLC Method for Bilastine Estimation in Pharmaceutical and Bulk Dose Form

Journal of chemical health risks
Chemical and Physical Properties in Aqueous Solutions
article

New RP-HPLC Method for Bilastine Estimation in Pharmaceutical and Bulk Dose Form

article en

Abstract

Bilastine is a frequently prescribed H1-antihistaminic that is authorized for the safe and efficient symptomatic management of allergic conditions, such as urticaria and rhino conjunctivitis. For the quick and precise measurement of bilastine, an Agilent Technologies LC compact 1120 module, a Shimadzu UV-1700 detector with a 20µl injection volume, and an xBridge TM C18 column were used in developing the validated Reverse Phase HPLC method. The procedure used a mobile phase made up of a 60:40, v/v% combination of methanol, 10 mM potassium dihydrogen phosphate at pH 3.5. By using the working standard solution, 10 µg/ml, satisfactory linearity shown over 5–30 µg/ml concentration range (correlation coefficient: 0.9924). Detection was done at 275 nm with a five-minute reaction time and the flow rate was maintained at 1.0 ml/min. The precision, accuracy, linearity, and robustness of the approach were confirmed by statistical validation in compliance with ICH criteria. This implies that the method for figuring out the tablet formulations is suitable. DOI: https://doi.org/10.52783/jchr.v15.i2.7707

Journal of chemical health risks
Zero hunger
Openalex Percentile: Top 94%
Chemical and Physical Properties in Aqueous Solutions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.