Quantitative Analysis of Muscarinic Antagonist Atropine and Tiotropium in Microvolume Plasma Using Liquid Chromatography–Mass Spectrometry: Application for Pharmacokinetic Studies

Despite the availability of current resources, the development of medical countermeasures remains crucial in combatting the threat posed by chemical warfare agents, such as organophosphorus compounds (OPs), which are toxic nerve agents requiring rapid medical intervention. Within the available therapeutic arsenal, muscarinic antagonists such as atropine are administered to mitigate the effects of excessive cholinergic system stimulation, which leads to respiratory tract obstruction due to hypersecretions and bronchoconstriction. Tiotropium, an FDA-approved bronchodilator, acts as a muscarinic receptor antagonist and could, therefore, serve as a potential alternative. To assess its potential efficacy in attenuating OP-induced respiratory effects in a murine intoxication model, it was necessary to first characterize its pharmacokinetic properties. A liquid chromatography-mass spectrometry method was developed and validated following ICH M10 guidelines for the quantification of atropine and tiotropium in 10 μL of plasma. The sample pretreatment procedure involved solid-phase extraction. Chromatographic separation was achieved using a fully porous sub 2 μm C18 column. The analysis was completed in just 4 min, with analytes identified and quantified using two selected reaction monitoring transitions. The mean extraction recoveries exceeded 90% for both drugs, and no matrix effect was observed. The lower limits of quantification were 0.5 ng/mL for tiotropium and 1.0 ng/mL for atropine, with an upper limit of 1000 ng/mL. The signal-to-concentration ratio demonstrated recoveries of back-calculated concentrations ranging from 94% to 108% (relative standard deviation (RSD) < 9.0%). Within-run and between-run precisions were both below 8% with accuracies ranging from 87% to 110%. This highly specific and sensitive method has proven useful for analyzing samples from pharmacokinetic studies conducted in mice. Following intraperitoneal administration, the AUC for tiotropium was approximately twice that of atropine, while its Tmax was half as long (4.9 vs. 8.2 min). The terminal half-lives were approximately 7.5 min for tiotropium and 9.8 min for atropine.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Methods in Chemistry
Published
2025-01-01
DOI
https://doi.org/10.1155/jamc/9923229
Citations
2
Primary Topic
Pesticide Exposure and Toxicity
Type
article
Field-Weighted Citation Impact
3.50

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Analysis of Muscarinic Antagonist Atropine and Tiotropium in Microvolume Plasma Using Liquid Chromatography–Mass Spectrometry: Application for Pharmacokinetic Studies

Nicolas Taudon, Gwladys Meesemaecker, Marilène Trancart, Romain Boffy et al.
2 citations
Journal of Analytical Methods in Chemistry
Pesticide Exposure and Toxicity
3.50
article

Quantitative Analysis of Muscarinic Antagonist Atropine and Tiotropium in Microvolume Plasma Using Liquid Chromatography–Mass Spectrometry: Application for Pharmacokinetic Studies

Nicolas Taudon, Gwladys Meesemaecker, Marilène Trancart, Romain Boffy, André-Guilhem Calas, Anne‐Sophie Hanak, Mylène Penot
article en
2 citations

Abstract

Despite the availability of current resources, the development of medical countermeasures remains crucial in combatting the threat posed by chemical warfare agents, such as organophosphorus compounds (OPs), which are toxic nerve agents requiring rapid medical intervention. Within the available therapeutic arsenal, muscarinic antagonists such as atropine are administered to mitigate the effects of excessive cholinergic system stimulation, which leads to respiratory tract obstruction due to hypersecretions and bronchoconstriction. Tiotropium, an FDA-approved bronchodilator, acts as a muscarinic receptor antagonist and could, therefore, serve as a potential alternative. To assess its potential efficacy in attenuating OP-induced respiratory effects in a murine intoxication model, it was necessary to first characterize its pharmacokinetic properties. A liquid chromatography-mass spectrometry method was developed and validated following ICH M10 guidelines for the quantification of atropine and tiotropium in 10 μL of plasma. The sample pretreatment procedure involved solid-phase extraction. Chromatographic separation was achieved using a fully porous sub 2 μm C18 column. The analysis was completed in just 4 min, with analytes identified and quantified using two selected reaction monitoring transitions. The mean extraction recoveries exceeded 90% for both drugs, and no matrix effect was observed. The lower limits of quantification were 0.5 ng/mL for tiotropium and 1.0 ng/mL for atropine, with an upper limit of 1000 ng/mL. The signal-to-concentration ratio demonstrated recoveries of back-calculated concentrations ranging from 94% to 108% (relative standard deviation (RSD) < 9.0%). Within-run and between-run precisions were both below 8% with accuracies ranging from 87% to 110%. This highly specific and sensitive method has proven useful for analyzing samples from pharmacokinetic studies conducted in mice. Following intraperitoneal administration, the AUC for tiotropium was approximately twice that of atropine, while its Tmax was half as long (4.9 vs. 8.2 min). The terminal half-lives were approximately 7.5 min for tiotropium and 9.8 min for atropine.

Journal of Analytical Methods in ChemistryVol. 2025(1)
Asur Plant Breeding (France) (FR), Biomedical Research Institute (US)
Ministère des Armées
Openalex Percentile: Top 9%
Pesticide Exposure and Toxicity
3.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.