A tribological investigation of cochlear implant electrode arrays with different wire shapes

The elasticity and frictional dynamics of a cochlear implant electrode array (EA) with different wire shapes are investigated by numerical and experimental analysis. Finite element method (FEM) analysis with varying wavelengths under large deformations indicates that the corrugated wire exhibits enhanced flexibility in both the transverse and longitudinal directions , while the buckling limit of the EA is governed by the wavelength of the wires. The friction experiments are carried out on a flat surface and an artificial cochlea model at different preloads, speeds and surface conditions, and the resulting data are analyzed using friction loops. It is found that wavy wired EA has a lower friction response and insertion force, while they are more prone to tip buckling and electrode array tip fold-over.

Authors

Institutions

Publication Details

Journal
Tribology International
Published
2025-04-08
DOI
https://doi.org/10.1016/j.triboint.2025.110679
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A tribological investigation of cochlear implant electrode arrays with different wire shapes

Gülçin Şefiye Aşkın, Bilsay Sümer
Tribology International
Hearing Loss and Rehabilitation
article

A tribological investigation of cochlear implant electrode arrays with different wire shapes

Gülçin Şefiye Aşkın, Bilsay Sümer
article en

Abstract

The elasticity and frictional dynamics of a cochlear implant electrode array (EA) with different wire shapes are investigated by numerical and experimental analysis. Finite element method (FEM) analysis with varying wavelengths under large deformations indicates that the corrugated wire exhibits enhanced flexibility in both the transverse and longitudinal directions , while the buckling limit of the EA is governed by the wavelength of the wires. The friction experiments are carried out on a flat surface and an artificial cochlea model at different preloads, speeds and surface conditions, and the resulting data are analyzed using friction loops. It is found that wavy wired EA has a lower friction response and insertion force, while they are more prone to tip buckling and electrode array tip fold-over.

Tribology InternationalVol. 209
Beytepe Asker Hastanesi (TR), Hacettepe University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, Hacettepe Üniversitesi
Openalex Percentile: Top 93%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.