PERFORMANCE OF THE DELTA MODULATION SYSTEM WITH VARIOUS DELTA STEP SIZES

Delta Modulation Systems are widely used in Analog-to-Digital Converter (ADC) systems. This research aims to determine the optimal delta step size that can be achieved in a Delta Modulation system, as the system's performance is highly influenced by the delta step size. The method used involves simulations with MATLAB to identify the optimal delta step value. The performance of a Delta Modulation system is greatly influenced by the Delta step size. The optimal value in this study was achieved at a Delta step size of 0.4 with the smallest error, namely MSE = 0.1186. If the Delta step size is smaller or larger than this optimal value, the MSE increases. When the frequency of the input signal increases, the Delta step size needs to be increased to follow the changes in the input signal. Otherwise, the MSE will also increase, a phenomenon known as Slope-overload Distortion. Granular Noise occurs when the input signal changes very slowly or is almost constant, while the step size is too large, resulting in a high MSE. To overcome this problem, a dynamic Delta step size is needed, adjusted to the frequency changes of the input signal. Such a system with a dynamic Delta step size is known as Adaptive Delta Modulation.

Authors

Institutions

Publication Details

Journal
Jurnal Techno Nusa Mandiri
Published
2025-03-14
DOI
https://doi.org/10.33480/techno.v22i1.6474
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PERFORMANCE OF THE DELTA MODULATION SYSTEM WITH VARIOUS DELTA STEP SIZES

Andi Rosano, Djadjat Sudaradjat
Jurnal Techno Nusa Mandiri
Plasma Diagnostics and Applications
article

PERFORMANCE OF THE DELTA MODULATION SYSTEM WITH VARIOUS DELTA STEP SIZES

Andi Rosano, Djadjat Sudaradjat
article en

Abstract

Delta Modulation Systems are widely used in Analog-to-Digital Converter (ADC) systems. This research aims to determine the optimal delta step size that can be achieved in a Delta Modulation system, as the system's performance is highly influenced by the delta step size. The method used involves simulations with MATLAB to identify the optimal delta step value. The performance of a Delta Modulation system is greatly influenced by the Delta step size. The optimal value in this study was achieved at a Delta step size of 0.4 with the smallest error, namely MSE = 0.1186. If the Delta step size is smaller or larger than this optimal value, the MSE increases. When the frequency of the input signal increases, the Delta step size needs to be increased to follow the changes in the input signal. Otherwise, the MSE will also increase, a phenomenon known as Slope-overload Distortion. Granular Noise occurs when the input signal changes very slowly or is almost constant, while the step size is too large, resulting in a high MSE. To overcome this problem, a dynamic Delta step size is needed, adjusted to the frequency changes of the input signal. Such a system with a dynamic Delta step size is known as Adaptive Delta Modulation.

Jurnal Techno Nusa MandiriVol. 22(1)
Universitas Informatika dan Bisnis Indonesia (ID)
Openalex Percentile: Top 94%
Plasma Diagnostics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

PERFORMANCE OF THE DELTA MODULATION SYSTEM WITH VARIOUS DELTA STEP SIZES — Andi Rosano, Djadjat Sudaradjat · Jurnal Techno Nusa Mandiri (2025) | TGRS Research Map | TGRS