Quantification of Nanoplastics and Inorganic Nanoparticles via Laser‐Induced Breakdown Detection (LIBD)

Nanoparticles with diverse characteristics are difficult to quantify at low concentrations in the water environment (10<sup>6</sup>-10<sup>9</sup> particles mL<sup>-1</sup> for nanoplastics originating from the breakdown of plastic debris) for the evaluation of effective treatment methods. This study examines the sensitivity, or limit of detection (LOD), of laser-induced breakdown detection (LIBD) for the counting of nanoparticles, including nanoplastics. For polystyrene (PS) standards with sizes of 20-400 nm, LIBD shows relatively low LODs (for example, 2 × 10<sup>6</sup> particles mL<sup>-1</sup> for 100 nm particles) compared with turbidity monitoring, UV-vis spectroscopy (both 6 × 10<sup>8</sup> particles mL<sup>-1</sup>), and nanoparticle tracking analysis (2 × 10<sup>7</sup> particles mL<sup>-1</sup>). For nanoplastics (PS, polypropylene, and polyethylene terephthalate), the detection limits are 10<sup>4</sup> - 10<sup>5</sup> particles mL<sup>-1</sup>, one to two orders of magnitude lower than the PS standards. LIBD can quantify inorganic nanoparticles, such as zeolite, titania, and hematite. The sensitivity increases (i.e., LOD reduces) with increasing particle density, while some particles are prone to artifacts. The low LODs make LIBD a robust technique for counting nanoparticles of various types and sizes, even at the concentrations found in the permeate of membrane-based water treatment systems. Given the high sensitivity, LIBD has the potential to be applied in membrane integrity monitoring and fundamental studies on membrane mechanisms.

Authors

Institutions

Publication Details

Journal
Small Methods
Published
2025-04-08
DOI
https://doi.org/10.1002/smtd.202402060
Citations
6
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
3.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of Nanoplastics and Inorganic Nanoparticles via Laser‐Induced Breakdown Detection (LIBD)

Minh Nhat Nguyen, Andrea I. Schäfer, Ines Zucker, Pia Lipp
6 citations
Small Methods
Microplastics and Plastic Pollution
3.02
article

Quantification of Nanoplastics and Inorganic Nanoparticles via Laser‐Induced Breakdown Detection (LIBD)

Minh Nhat Nguyen, Andrea I. Schäfer, Ines Zucker, Pia Lipp
article en
6 citations

Abstract

Nanoparticles with diverse characteristics are difficult to quantify at low concentrations in the water environment (10<sup>6</sup>-10<sup>9</sup> particles mL<sup>-1</sup> for nanoplastics originating from the breakdown of plastic debris) for the evaluation of effective treatment methods. This study examines the sensitivity, or limit of detection (LOD), of laser-induced breakdown detection (LIBD) for the counting of nanoparticles, including nanoplastics. For polystyrene (PS) standards with sizes of 20-400 nm, LIBD shows relatively low LODs (for example, 2 × 10<sup>6</sup> particles mL<sup>-1</sup> for 100 nm particles) compared with turbidity monitoring, UV-vis spectroscopy (both 6 × 10<sup>8</sup> particles mL<sup>-1</sup>), and nanoparticle tracking analysis (2 × 10<sup>7</sup> particles mL<sup>-1</sup>). For nanoplastics (PS, polypropylene, and polyethylene terephthalate), the detection limits are 10<sup>4</sup> - 10<sup>5</sup> particles mL<sup>-1</sup>, one to two orders of magnitude lower than the PS standards. LIBD can quantify inorganic nanoparticles, such as zeolite, titania, and hematite. The sensitivity increases (i.e., LOD reduces) with increasing particle density, while some particles are prone to artifacts. The low LODs make LIBD a robust technique for counting nanoparticles of various types and sizes, even at the concentrations found in the permeate of membrane-based water treatment systems. Given the high sensitivity, LIBD has the potential to be applied in membrane integrity monitoring and fundamental studies on membrane mechanisms.

Small MethodsVol. 9(9)
Karlsruhe Institute of Technology (DE), Tel Aviv University (IL), DVGW - Technologiezentrum Wasser (DE)
Lieber Institute for Brain Development, Deutscher Akademischer Austauschdienst, Bundesministerium für Bildung und Forschung
Clean water and sanitation
Openalex Percentile: Top 9%
Microplastics and Plastic Pollution
3.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.