Effect of Polymeric Moisture Barriers on ZnO Nanofiber Gas Sensors Operating at Room Temperature

Relative humidity is a significant factor that impairs gas sensor performance. Some investigations have heated sensors to temperatures beyond 100 °C to eliminate relative humidity, negatively affecting the sensor stability and application range. To improve the sensitivity of gas sensors that operate at room temperatures, free-standing polymer films with moisture barrier qualities are applied to various sensor architectures. A selective permeable polymer membrane applied to the air interface of the sensors, with or without contact, is intended to lessen the effects of relative humidity on sensor sensitivity. In this study, ZnO structures were synthesized by using electrospinning methods. Selective permeable polystyrene/poly(ethylene glycol) (PS/PEG) polymer film membranes were produced on the synthesized nanofiber structures and applied to the sensor. In the membrane synthesis, the CO<sub>2</sub> annealing process was applied to control the porosity O<sub>2</sub> and moisture permeability. Gas sensor performance tests for NO<sub>2</sub> and H<sub>2</sub> gases were conducted for these synthesized nanostructures and membranes by using various characterization techniques and analyses. Gas-sensing measurements were performed in dry air and a relative humidity (RH) of 50%, employing different concentrations of NO<sub>2</sub> and H<sub>2</sub> gases. Different sensing parameters (response time, recovery time, sensitivity) were estimated at room temperature for samples, and the sensor sensitivity was 0.0152 at 50 ppm. Sensor response is enhanced approximately fivefold by samples with polymeric membrane measurements compared to without. Nanofibers exhibit 120 and 300 s response time and recovery time for NO<sub>2</sub> gas, respectively. As a result, a new approach to the literature has been provided to reduce the effects of RH on the sensor, which is one of the biggest obstacles in the scope of gas sensors operating at room temperature. Therefore, this study's findings open a general approach for fabricating flexible devices for gas detection applications.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-04-08
DOI
https://doi.org/10.1021/acsomega.5c00664
Citations
1
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Polymeric Moisture Barriers on ZnO Nanofiber Gas Sensors Operating at Room Temperature

Selda Topçu Şendoğdular, Levent Şendoğdular
1 citations
ACS Omega
Gas Sensing Nanomaterials and Sensors
0.73
article

Effect of Polymeric Moisture Barriers on ZnO Nanofiber Gas Sensors Operating at Room Temperature

Selda Topçu Şendoğdular, Levent Şendoğdular
article en
1 citations

Abstract

Relative humidity is a significant factor that impairs gas sensor performance. Some investigations have heated sensors to temperatures beyond 100 °C to eliminate relative humidity, negatively affecting the sensor stability and application range. To improve the sensitivity of gas sensors that operate at room temperatures, free-standing polymer films with moisture barrier qualities are applied to various sensor architectures. A selective permeable polymer membrane applied to the air interface of the sensors, with or without contact, is intended to lessen the effects of relative humidity on sensor sensitivity. In this study, ZnO structures were synthesized by using electrospinning methods. Selective permeable polystyrene/poly(ethylene glycol) (PS/PEG) polymer film membranes were produced on the synthesized nanofiber structures and applied to the sensor. In the membrane synthesis, the CO<sub>2</sub> annealing process was applied to control the porosity O<sub>2</sub> and moisture permeability. Gas sensor performance tests for NO<sub>2</sub> and H<sub>2</sub> gases were conducted for these synthesized nanostructures and membranes by using various characterization techniques and analyses. Gas-sensing measurements were performed in dry air and a relative humidity (RH) of 50%, employing different concentrations of NO<sub>2</sub> and H<sub>2</sub> gases. Different sensing parameters (response time, recovery time, sensitivity) were estimated at room temperature for samples, and the sensor sensitivity was 0.0152 at 50 ppm. Sensor response is enhanced approximately fivefold by samples with polymeric membrane measurements compared to without. Nanofibers exhibit 120 and 300 s response time and recovery time for NO<sub>2</sub> gas, respectively. As a result, a new approach to the literature has been provided to reduce the effects of RH on the sensor, which is one of the biggest obstacles in the scope of gas sensors operating at room temperature. Therefore, this study's findings open a general approach for fabricating flexible devices for gas detection applications.

ACS OmegaVol. 10(15)
Erciyes University (TR)
Erciyes Üniversitesi, Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Affordable and clean energy
Openalex Percentile: Top 30%
Gas Sensing Nanomaterials and Sensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.