Patient-specific channelized hotelling observer to estimate lesion detectability in CT

Task-based image quality assessment is essential for CT protocol and radiation dose optimization. Despite many ongoing efforts, there is still an unmet need to measure and monitor the quality of images acquired from each patient exam. In this work, we developed a patient-specific channelized Hotelling observer (CHO)-based method to estimate the lesion detectability for each individual patient scan. The ensemble of background was created from patient images to include both relatively uniform regions and anatomically varying regions. Signals were modelled from lesions of different sizes and contrast levels after incorporating the effect of contrast-dependent spatial resolution. Index of detectability (d') was estimated using a CHO framework. This method was applied to clinical patient images obtained from a CT scanner at 3 different radiation dose levels. The d' for 5 different lesion size/contrast conditions was calculated across the scan range of each patient exam. The average noise levels and the d' averaged from 5 conditions were 13.2/3.78, 17.1/2.93 and 21.9/2.43 at 100%, 50% and 25% dose levels, respectively.

Authors

Institutions

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3047381
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient-specific channelized hotelling observer to estimate lesion detectability in CT

Lifeng Yu, Cynthia H. McCollough, Jarod Wellinghoff, Zhongxing Zhou
Advanced X-ray and CT Imaging
article

Patient-specific channelized hotelling observer to estimate lesion detectability in CT

Lifeng Yu, Cynthia H. McCollough, Jarod Wellinghoff, Zhongxing Zhou
article en

Abstract

Task-based image quality assessment is essential for CT protocol and radiation dose optimization. Despite many ongoing efforts, there is still an unmet need to measure and monitor the quality of images acquired from each patient exam. In this work, we developed a patient-specific channelized Hotelling observer (CHO)-based method to estimate the lesion detectability for each individual patient scan. The ensemble of background was created from patient images to include both relatively uniform regions and anatomically varying regions. Signals were modelled from lesions of different sizes and contrast levels after incorporating the effect of contrast-dependent spatial resolution. Index of detectability (d') was estimated using a CHO framework. This method was applied to clinical patient images obtained from a CT scanner at 3 different radiation dose levels. The d' for 5 different lesion size/contrast conditions was calculated across the scan range of each patient exam. The average noise levels and the d' averaged from 5 conditions were 13.2/3.78, 17.1/2.93 and 21.9/2.43 at 100%, 50% and 25% dose levels, respectively.

Vol. 13405
Mayo Clinic in Arizona (US)
National Institutes of Health
Climate action
Openalex Percentile: Top 93%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.