Patlak reconstruction from dynamic PET based on diffusion models: evaluations using total-body dynamic datasets

Dynamic PET can quantitatively recover physiology-related parameters. It is widely used in research and is being adopted in clinics. For dynamic PET, kinetic modeling is needed to reconstruct parametric images based on a specific kinetic model. The parametric images reconstructed always suffer from low image quality, mainly due to the ill-posedness of kinetic-model fitting and limited counts due to non-continuous data acquisition for each bed position. In this work, we proposed a diffusion model-based kinetic-model fitting framework, with Patlak model as one example. For this proposed framework, the score function was pre-trained based on static total-body PET images and utilized as the prior for Patlak slope and intercept images, considering the patch-wise similarity among them. During inference, the Patlak kinetic model was employed as a data-consistency constraint to generate the final Patlak images. Preliminary results based on total-body dynamic datasets demonstrated the feasibility and promising performance of the proposed framework.

Authors

Institutions

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3047521
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patlak reconstruction from dynamic PET based on diffusion models: evaluations using total-body dynamic datasets

Boxiao Yu, Kuang Gong, Siqi Li, Zheying Huang et al.
Medical Imaging Techniques and Applications
article

Patlak reconstruction from dynamic PET based on diffusion models: evaluations using total-body dynamic datasets

Boxiao Yu, Kuang Gong, Siqi Li, Zheying Huang, Guobao Wang
article en

Abstract

Dynamic PET can quantitatively recover physiology-related parameters. It is widely used in research and is being adopted in clinics. For dynamic PET, kinetic modeling is needed to reconstruct parametric images based on a specific kinetic model. The parametric images reconstructed always suffer from low image quality, mainly due to the ill-posedness of kinetic-model fitting and limited counts due to non-continuous data acquisition for each bed position. In this work, we proposed a diffusion model-based kinetic-model fitting framework, with Patlak model as one example. For this proposed framework, the score function was pre-trained based on static total-body PET images and utilized as the prior for Patlak slope and intercept images, considering the patch-wise similarity among them. During inference, the Patlak kinetic model was employed as a data-consistency constraint to generate the final Patlak images. Preliminary results based on total-body dynamic datasets demonstrated the feasibility and promising performance of the proposed framework.

University of Florida (US), University of California, Davis (US)
Openalex Percentile: Top 89%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Patlak reconstruction from dynamic PET based on diffusion models: evaluations using total-body dynamic datasets — Boxiao Yu, Kuang Gong, et al. · (2025) | TGRS Research Map | TGRS