Motion compensation in cardiac CT for the entire heart using a residual U-Net

Cardiac motion remains a major challenge in maintaining image quality in cardiac CT. Despite continuous progress in temporal resolution and scan protocol optimization, there are still cases where the heart moves up to several millimeters during a scan. This can result in severe motion artifacts in the corresponding CT reconstructions, diminishing the diagnostic value of the scan. A prevalent method to address these artifacts and enhance temporal resolution is based on so-called partial angle reconstructions (PARs). In this approach, the scan is divided into multiple angular intervals, each reconstructed individually. Motion between these PARs is then corrected by applying motion vector fields (MVFs). After deforming all PARs to the same reference motion state using these MVFs, they are summed to produce the final, artifact-free reconstruction. Unlike existing techniques that focus on small areas around the coronary arteries, this work expands the strategy to encompass the entire heart. A residual U-net is trained to predict MVFs based for a given PARs. When applied to test data, the proposed method effectively eliminates nearly all motion artifacts across various heart regions, including the coronary arteries and cardiac valves. Consequently, the average mean absolute error (MAE) for the entire heart, in comparison to a motion artifact ground truth, was reduced from 32.74 HU to 8.37 HU.

Authors

Institutions

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3048937
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Motion compensation in cardiac CT for the entire heart using a residual U-Net

Joscha Maier, Marc Kachelrieß, Li Ou
Advanced X-ray and CT Imaging
article

Motion compensation in cardiac CT for the entire heart using a residual U-Net

Joscha Maier, Marc Kachelrieß, Li Ou
article en

Abstract

Cardiac motion remains a major challenge in maintaining image quality in cardiac CT. Despite continuous progress in temporal resolution and scan protocol optimization, there are still cases where the heart moves up to several millimeters during a scan. This can result in severe motion artifacts in the corresponding CT reconstructions, diminishing the diagnostic value of the scan. A prevalent method to address these artifacts and enhance temporal resolution is based on so-called partial angle reconstructions (PARs). In this approach, the scan is divided into multiple angular intervals, each reconstructed individually. Motion between these PARs is then corrected by applying motion vector fields (MVFs). After deforming all PARs to the same reference motion state using these MVFs, they are summed to produce the final, artifact-free reconstruction. Unlike existing techniques that focus on small areas around the coronary arteries, this work expands the strategy to encompass the entire heart. A residual U-net is trained to predict MVFs based for a given PARs. When applied to test data, the proposed method effectively eliminates nearly all motion artifacts across various heart regions, including the coronary arteries and cardiac valves. Consequently, the average mean absolute error (MAE) for the entire heart, in comparison to a motion artifact ground truth, was reduced from 32.74 HU to 8.37 HU.

German Cancer Research Center (DE), Heidelberg University (DE), DKFZ-ZMBH Alliance (DE)
Openalex Percentile: Top 93%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Motion compensation in cardiac CT for the entire heart using a residual U-Net — Joscha Maier, Marc Kachelrieß, et al. · (2025) | TGRS Research Map | TGRS