Deep bowtie and patient scatter correction applied to clinical photon-counting CT

In addition to the objects or patients that are scanned in a CT, other components in the beam path can also cause scatter. In particular, scatter by the bowtie filter, which is typically the last filter before the patient, can create image artifacts, impair contrast and considerably distort the CT values. Previous studies have shown that deep convolutional neural networks are very effective correcting scattered photons in clinical CTs. In this work, we present an adapted approach of the deep scatter estimation (DSE) method for photon-counting (PC) CT that effectively corrects both object and bowtie scatter. Our best network reduces the mean absolute error of object and bowtie scatter from 8.1 HU to 0.9 HU.

Authors

Institutions

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3047966
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep bowtie and patient scatter correction applied to clinical photon-counting CT

Karl Stierstorfer, Marc Kachelrieß, Éric Fournié, Joseph Meier et al.
1 citations
Advanced X-ray and CT Imaging
0.67
article

Deep bowtie and patient scatter correction applied to clinical photon-counting CT

Karl Stierstorfer, Marc Kachelrieß, Éric Fournié, Joseph Meier, Lukas Hennemann, Martin Petersilka, Julien Erath, Andreas Heinkele
article en
1 citations

Abstract

In addition to the objects or patients that are scanned in a CT, other components in the beam path can also cause scatter. In particular, scatter by the bowtie filter, which is typically the last filter before the patient, can create image artifacts, impair contrast and considerably distort the CT values. Previous studies have shown that deep convolutional neural networks are very effective correcting scattered photons in clinical CTs. In this work, we present an adapted approach of the deep scatter estimation (DSE) method for photon-counting (PC) CT that effectively corrects both object and bowtie scatter. Our best network reduces the mean absolute error of object and bowtie scatter from 8.1 HU to 0.9 HU.

German Cancer Research Center (DE), Heidelberg University (DE), DKFZ-ZMBH Alliance (DE), Siemens Healthineers (Germany) (DE)
Openalex Percentile: Top 33%
Advanced X-ray and CT Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.