Reducing scatter and cone-beam artifacts in DE-CBCT

This study evaluates the feasibility of reducing scatter and cone beam artifacts in dual-energy CBCT (DE-CBCT) by using an axially collimated carbon nanotube (CNT) x-ray source array with interlaced spectral filters. A benchtop CBCT scanner with an energy integrating flat panel detector (FPD), a CNT x-ray source array, and a rotating gantry was used. X-ray photons from even-number focal spots were filtered by a low-energy (LE) filter, while those from the odd-number spots by a high-energy (HE) filter. The x-ray photons from each focal spot was confined by an external collimator to illuminate only a section of the object. DE-CBCT images were collected by cycling the eight beams sequentially during a full gantry rotation. An existing one-step materials decomposition and reconstruction method was modified for this specific imaging configuration. Phantom imaging studies showed significantly reduced cupping and cone beam artifacts, increased accuracy in material quantification, and enhanced image contrast compared to a regular DE-CBCT.

Authors

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3044778
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing scatter and cone-beam artifacts in DE-CBCT

Christina R. Inscoe, Otto Zhou, Jianping Lü, Donald A. Tyndall et al.
1 links
Medical Imaging Techniques and Applications
article

Reducing scatter and cone-beam artifacts in DE-CBCT

Christina R. Inscoe, Otto Zhou, Jianping Lü, Donald A. Tyndall, Yuanming Hu, Yueh Z. Lee, Boyuan Li, Shuang Xu
article en

Abstract

This study evaluates the feasibility of reducing scatter and cone beam artifacts in dual-energy CBCT (DE-CBCT) by using an axially collimated carbon nanotube (CNT) x-ray source array with interlaced spectral filters. A benchtop CBCT scanner with an energy integrating flat panel detector (FPD), a CNT x-ray source array, and a rotating gantry was used. X-ray photons from even-number focal spots were filtered by a low-energy (LE) filter, while those from the odd-number spots by a high-energy (HE) filter. The x-ray photons from each focal spot was confined by an external collimator to illuminate only a section of the object. DE-CBCT images were collected by cycling the eight beams sequentially during a full gantry rotation. An existing one-step materials decomposition and reconstruction method was modified for this specific imaging configuration. Phantom imaging studies showed significantly reduced cupping and cone beam artifacts, increased accuracy in material quantification, and enhanced image contrast compared to a regular DE-CBCT.

Openalex Percentile: Top 89%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.