Composition optimization of cement-gypsum based silica aerogel with low thermal conductivity insulation mortar

Although the thermal conductivity of mortar can be effectively reduced by adding appropriate amount of SiO 2 aerogel to the inorganic cementitious material matrix , the thermal conductivity of thermal insulation mortar is still different from that of organic thermal insulation materials . Therefore, in order to further reduce the thermal conductivity , this paper optimized the composition and formula of cement gypsum silica aerogel thermal insulation mortar. To explore the influence of the amount of polystyrene particles (EPS) (3.9 kg/m 3 , 5.2 kg/m 3 , 6.5 kg/m 3 ), the amount of aerogel instead of gypsum (30 wt%, 40 wt%, 50 wt%) and the silica fume ratio of mineral powder (4:1, 1:1, 1:4) on the thermal conductivity, density and compressive strength of mortar. By using X-ray diffraction, scanning electron microscopy, and nuclear magnetic resonance analysis, the mineral composition, microstructure, and pore size distribution of mortar were studied to clarify the correlation between the microstructure of insulation mortar and its insulation performance. The results show that: The influence degree of the above three factors on thermal conductivity and compressive strength of thermal insulation mortar specimens is ranked as follows: silica fume ratio of mineral powder > EPS particle content > aerogel content. The order of influence degree on density is: EPS particle content > silica fume ratio of mineral powder > aerogel content. When the EPS particle content is 5.2 kg/m 3 , the aerogel content is 30 wt%, and the ratio of mineral powder to silica fume is 4:1, the thermal conductivity of the thermal insulation mortar specimen is 0.032 W/(m∙k), the density is 0.18 g/cm 3 , and the compressive strength is 0.09 MPa. Changing the composition parameters of the mortar do not alter the mineral composition of the insulation mortar specimens, only the degree of hydration. As the thermal conductivity of mortar decreases, the volume of macropores inside the mortar gradually decreases (decreasing by 13.9 % and 33.2 % respectively), while the volume of transition pores and capillary pores gradually increases (increasing by 6.7 %、29.4 % and 2.6 %、4.6 % respectively). • The influence degree of three different factors on thermal conductivity of thermal insulation mortar is: silica fume ratio of mineral powder > EPS particle content > aerogel content. • Cement gypsum aerogel thermal insulation mortar with thermal conductivity as low as 0.032 W/(m∙k) was prepared. • Changing the composition parameters of the mortar do not alter the mineral composition of the insulation mortar specimens, only the degree of hydration. • As the thermal conductivity of mortar decreases, the volume of macropores inside the mortar gradually decreases, while the volume of transition pores and capillary pores gradually increases.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2025-04-08
DOI
https://doi.org/10.1016/j.jobe.2025.112630
Citations
4
Primary Topic
Aerogels and thermal insulation
Type
article
Field-Weighted Citation Impact
3.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Composition optimization of cement-gypsum based silica aerogel with low thermal conductivity insulation mortar

S.-P. Wang, Xiaomin Liu, Zhihua Liu, Xiangyang Chen et al.
4 citations
Journal of Building Engineering
Aerogels and thermal insulation
3.03
article

Composition optimization of cement-gypsum based silica aerogel with low thermal conductivity insulation mortar

S.-P. Wang, Xiaomin Liu, Zhihua Liu, Xiangyang Chen, Hui Rong, Dee Liu, Keqi Huang
article en
4 citations

Abstract

Although the thermal conductivity of mortar can be effectively reduced by adding appropriate amount of SiO 2 aerogel to the inorganic cementitious material matrix , the thermal conductivity of thermal insulation mortar is still different from that of organic thermal insulation materials . Therefore, in order to further reduce the thermal conductivity , this paper optimized the composition and formula of cement gypsum silica aerogel thermal insulation mortar. To explore the influence of the amount of polystyrene particles (EPS) (3.9 kg/m 3 , 5.2 kg/m 3 , 6.5 kg/m 3 ), the amount of aerogel instead of gypsum (30 wt%, 40 wt%, 50 wt%) and the silica fume ratio of mineral powder (4:1, 1:1, 1:4) on the thermal conductivity, density and compressive strength of mortar. By using X-ray diffraction, scanning electron microscopy, and nuclear magnetic resonance analysis, the mineral composition, microstructure, and pore size distribution of mortar were studied to clarify the correlation between the microstructure of insulation mortar and its insulation performance. The results show that: The influence degree of the above three factors on thermal conductivity and compressive strength of thermal insulation mortar specimens is ranked as follows: silica fume ratio of mineral powder > EPS particle content > aerogel content. The order of influence degree on density is: EPS particle content > silica fume ratio of mineral powder > aerogel content. When the EPS particle content is 5.2 kg/m 3 , the aerogel content is 30 wt%, and the ratio of mineral powder to silica fume is 4:1, the thermal conductivity of the thermal insulation mortar specimen is 0.032 W/(m∙k), the density is 0.18 g/cm 3 , and the compressive strength is 0.09 MPa. Changing the composition parameters of the mortar do not alter the mineral composition of the insulation mortar specimens, only the degree of hydration. As the thermal conductivity of mortar decreases, the volume of macropores inside the mortar gradually decreases (decreasing by 13.9 % and 33.2 % respectively), while the volume of transition pores and capillary pores gradually increases (increasing by 6.7 %、29.4 % and 2.6 %、4.6 % respectively). • The influence degree of three different factors on thermal conductivity of thermal insulation mortar is: silica fume ratio of mineral powder > EPS particle content > aerogel content. • Cement gypsum aerogel thermal insulation mortar with thermal conductivity as low as 0.032 W/(m∙k) was prepared. • Changing the composition parameters of the mortar do not alter the mineral composition of the insulation mortar specimens, only the degree of hydration. • As the thermal conductivity of mortar decreases, the volume of macropores inside the mortar gradually decreases, while the volume of transition pores and capillary pores gradually increases.

Journal of Building EngineeringVol. 106
Tianjin University of Technology (CN), Tianjin University (CN), Tianjin Chengjian University (CN), China Railway Group (China) (CN), China State Construction Engineering (China) (CN)
Openalex Percentile: Top 9%
Aerogels and thermal insulation
3.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.