Urinary Bladder Volume Monitoring System With Antenna Array-Based Flexible Sensor

Urinary incontinence is one of the common problems that come with age and mostly affects older adults with dementia and other neurological disorders. Clinical research suggests that continence issues are better managed with continuous monitoring of bladder volume. Common existing catheter-based methods are invasive, uncomfortable, and may cause infection when used for a long duration. This article presents a non-invasive approach to monitoring urinary bladder volume using a sensing system configured with an antenna array for a narrow beam scan. The antenna array is designed and modeled in the CST simulator package, and simulations are conducted with a customized voxel pelvis bio model. The model resolution is set to 0.98×0.98×1 mm3, and the simulated environment is optimized to detect the urinary bladder contraction and expansion with approximate bladder volumes of 102 ml to 300 ml (changes in radii from 29 mm to 41 mm). For antenna array fabrication, a careful choice of flexible substrate has been made to make the sensor embeddable in a piece of furniture or chair. Experimental results are validated using the fabricated antenna, integrated with a prototype pelvis model made of PVC material (dielectric constant of 3.8 to 4.0). This sensing system effectively detects bladder fluid with a maximum range of 100 ml to 500 ml. The optimum results were obtained at a linear distance of 20 cm and an angular displacement of 60° in the experimental setup. The Specific Absorption Rate is evaluated for the safe application of the proposed sensor, which is 0.104438 W/kg (SAR < 0.4 W/kg) at the wavelength of 119.917 mm. The initial results indicate that the proposed sensing system is efficient and safe and shows good potential to integrate with monitoring setups for urology care.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-08
DOI
https://doi.org/10.1109/jsen.2025.3556631
Citations
1
Primary Topic
IoT-based Smart Home Systems
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Urinary Bladder Volume Monitoring System With Antenna Array-Based Flexible Sensor

Tughrul Arslan, Imran Saied, Samia Saher, Sadia Abdul Samad
1 citations
IEEE Sensors Journal
IoT-based Smart Home Systems
0.73
article

Urinary Bladder Volume Monitoring System With Antenna Array-Based Flexible Sensor

Tughrul Arslan, Imran Saied, Samia Saher, Sadia Abdul Samad
article en
1 citations

Abstract

Urinary incontinence is one of the common problems that come with age and mostly affects older adults with dementia and other neurological disorders. Clinical research suggests that continence issues are better managed with continuous monitoring of bladder volume. Common existing catheter-based methods are invasive, uncomfortable, and may cause infection when used for a long duration. This article presents a non-invasive approach to monitoring urinary bladder volume using a sensing system configured with an antenna array for a narrow beam scan. The antenna array is designed and modeled in the CST simulator package, and simulations are conducted with a customized voxel pelvis bio model. The model resolution is set to 0.98×0.98×1 mm3, and the simulated environment is optimized to detect the urinary bladder contraction and expansion with approximate bladder volumes of 102 ml to 300 ml (changes in radii from 29 mm to 41 mm). For antenna array fabrication, a careful choice of flexible substrate has been made to make the sensor embeddable in a piece of furniture or chair. Experimental results are validated using the fabricated antenna, integrated with a prototype pelvis model made of PVC material (dielectric constant of 3.8 to 4.0). This sensing system effectively detects bladder fluid with a maximum range of 100 ml to 500 ml. The optimum results were obtained at a linear distance of 20 cm and an angular displacement of 60° in the experimental setup. The Specific Absorption Rate is evaluated for the safe application of the proposed sensor, which is 0.104438 W/kg (SAR < 0.4 W/kg) at the wavelength of 119.917 mm. The initial results indicate that the proposed sensing system is efficient and safe and shows good potential to integrate with monitoring setups for urology care.

IEEE Sensors JournalVol. 25(11)
University of Edinburgh (GB)
Openalex Percentile: Top 30%
IoT-based Smart Home Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Urinary Bladder Volume Monitoring System With Antenna Array-Based Flexible Sensor — Tughrul Arslan, Imran Saied, et al. · IEEE Sensors Journal (2025) | TGRS Research Map | TGRS