Implications of Extra-column Effects for Targeted or Untargeted Microflow LC-MS

Mass spectrometry (MS) has changed our understanding of health, disease, and the environment through untargeted analyses where entire molecular classes are investigated. These techniques generate huge amounts of data which when processed by statistical tools can identify important molecular features or biomarkers. The complexities of these samples are not compatible with direct introduction to the MS system and require a high-resolution separation step, typically low flow liquid chromatography (LC), prior to MS. LC columns that can produce adequate linear velocities at these low flow rates are small in volume making their results susceptible to resolution loss in extra-column volumes. Here, we investigate the implications of the extra-column effects in five LC-MS systems with triple quadrupole and orbitrap mass analyzers. The extra-column volume of these systems in their standard configuration ranged from 26.4 to 78.1 μL which we reduced to 9.57 to 18.7 μL by optimizing the fluidics. The effects of this volume reduction were assessed by studying a hydrolyzed protein sample in a proteomics environment where the intensity of the largest MS peak was improved by 1.8-3.8×. Additionally, the number of molecular features detected in the protein sample improved by up to 7.5×. The relationship between extra-column volumetric variance and flow rate shows that broadening will become much larger for MS detectors at higher flow rates, unlike a traditional small volume UV detector. The methods, applications, and theoretical insights in this work can be used to improve the mass spectrometric results of any LC-MS system.

Authors

Institutions

Publication Details

Journal
ACS Measurement Science Au
Published
2025-04-08
DOI
https://doi.org/10.1021/acsmeasuresciau.5c00015
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implications of Extra-column Effects for Targeted or Untargeted Microflow LC-MS

Umang Dhaubhadel, Martin Novák, Ondřej Horáček, Troy T. Handlovic et al.
ACS Measurement Science Au
Mass Spectrometry Techniques and Applications
article

Implications of Extra-column Effects for Targeted or Untargeted Microflow LC-MS

Umang Dhaubhadel, Martin Novák, Ondřej Horáček, Troy T. Handlovic, Daniel W. Armstrong, Lucie Nováková
article en

Abstract

Mass spectrometry (MS) has changed our understanding of health, disease, and the environment through untargeted analyses where entire molecular classes are investigated. These techniques generate huge amounts of data which when processed by statistical tools can identify important molecular features or biomarkers. The complexities of these samples are not compatible with direct introduction to the MS system and require a high-resolution separation step, typically low flow liquid chromatography (LC), prior to MS. LC columns that can produce adequate linear velocities at these low flow rates are small in volume making their results susceptible to resolution loss in extra-column volumes. Here, we investigate the implications of the extra-column effects in five LC-MS systems with triple quadrupole and orbitrap mass analyzers. The extra-column volume of these systems in their standard configuration ranged from 26.4 to 78.1 μL which we reduced to 9.57 to 18.7 μL by optimizing the fluidics. The effects of this volume reduction were assessed by studying a hydrolyzed protein sample in a proteomics environment where the intensity of the largest MS peak was improved by 1.8-3.8×. Additionally, the number of molecular features detected in the protein sample improved by up to 7.5×. The relationship between extra-column volumetric variance and flow rate shows that broadening will become much larger for MS detectors at higher flow rates, unlike a traditional small volume UV detector. The methods, applications, and theoretical insights in this work can be used to improve the mass spectrometric results of any LC-MS system.

ACS Measurement Science AuVol. 5(3)
The University of Texas at Arlington (US), Charles University (CZ), University Hospital Hradec Králové (CZ), University of Hradec Králové (CZ)
Welch Foundation
Openalex Percentile: Top 93%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.