Simulating scanner- and algorithm-specific 3D CT noise texture using physics-informed 2D and 2.5D generative neural network models

Low-dose CT simulation is needed to assess reconstruction/denoising techniques and optimize dose. Projection-domain noise-insertion methods require manufacturers' proprietary tools. Image-domain noise-insertion methods face various challenges that affect generalizability, and few have been systematically validated for 3D noise synthesis. To improve generalizability, we presented a <b>p</b>hysics-informed model-based gener<b>a</b>tive neura<b>l</b> network for simulating scann<b>e</b>r- and algorithm-specific low-dose C<b>T e</b>xams (PALETTE). PALETTE included a noise-prior-generation process, a Noise2Noisier sub-network, and a noise-texture-synthesis sub-network. Custom regularization terms were developed to enforce 3D noise texture quality. Using PALETTE, one 2D and two 2.5D models (denoted as 2.5D <i>N-N</i> and <i>N-1</i>) were developed to conduct 2D and effective 3D noise modeling, respectively (input/output images: 2D - 1/1, 2.5D <i>N-N</i> - 3/3, 2.5D <i>N-1</i> - 5/1). These models were trained and tested with an open-access abdominal CT dataset, including 20 testing cases reconstructed with two kernels and various field-of-view. In visual inspection, the 2D and 2.5D <i>N-N</i> models generated realistic local and global noise texture, while 2.5D <i>N-1</i> showed more perceptual difference using the sharper kernel and coronal reformat. In quantitative evaluation, local noise level was compared using mean-absolute-percent-difference (MAPD), and global spectral similarity was assessed using spectral correlation mapper (SCM) and spectral angle mapper (SAM). The 2D model provided equivalent or relatively better performance than 2.5D models, showing well-matched local noise levels and high spectral similarity compared to the reference (sharper/smoother kernels): MAPD - 2D 1.5%/5.6% (p>0.05), 2.5D <i>N-N</i> 8.5%/7.9% (p<0.05), 2.5D <i>N-1</i> 12.3%/10.9% (p<0.05); mean SCM - 2D 0.97/0.97, 2.5D <i>N-N</i> 0.96/0.97, 2.5D <i>N-1</i> 0.85/0.97; mean SAM - 2D 0.12/0.12, 2.5D <i>N-N</i> 0.14/0.12, 2.5D <i>N-1</i> 0.37/0.12. With tripled model width, the 2.5D <i>N-N</i> outperformed <i>N-1</i>. This indicated 2.5D models need more learning capacity to further enhance 3D noise modeling. Using physics-based prior information, PALETTE can provide high-quality low-dose CT simulation to resemble scanner- and algorithm-specific 3D noise characteristics.

Authors

Institutions

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3047909
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulating scanner- and algorithm-specific 3D CT noise texture using physics-informed 2D and 2.5D generative neural network models

Hao Gong, Shuai Leng, Scott S. Hsieh, Thomas M. Huber et al.
Radiomics and Machine Learning in Medical Imaging
article

Simulating scanner- and algorithm-specific 3D CT noise texture using physics-informed 2D and 2.5D generative neural network models

Hao Gong, Shuai Leng, Scott S. Hsieh, Thomas M. Huber, Lifeng Yu, Cynthia H. McCollough, Timothy Winfree
article en

Abstract

Low-dose CT simulation is needed to assess reconstruction/denoising techniques and optimize dose. Projection-domain noise-insertion methods require manufacturers' proprietary tools. Image-domain noise-insertion methods face various challenges that affect generalizability, and few have been systematically validated for 3D noise synthesis. To improve generalizability, we presented a <b>p</b>hysics-informed model-based gener<b>a</b>tive neura<b>l</b> network for simulating scann<b>e</b>r- and algorithm-specific low-dose C<b>T e</b>xams (PALETTE). PALETTE included a noise-prior-generation process, a Noise2Noisier sub-network, and a noise-texture-synthesis sub-network. Custom regularization terms were developed to enforce 3D noise texture quality. Using PALETTE, one 2D and two 2.5D models (denoted as 2.5D <i>N-N</i> and <i>N-1</i>) were developed to conduct 2D and effective 3D noise modeling, respectively (input/output images: 2D - 1/1, 2.5D <i>N-N</i> - 3/3, 2.5D <i>N-1</i> - 5/1). These models were trained and tested with an open-access abdominal CT dataset, including 20 testing cases reconstructed with two kernels and various field-of-view. In visual inspection, the 2D and 2.5D <i>N-N</i> models generated realistic local and global noise texture, while 2.5D <i>N-1</i> showed more perceptual difference using the sharper kernel and coronal reformat. In quantitative evaluation, local noise level was compared using mean-absolute-percent-difference (MAPD), and global spectral similarity was assessed using spectral correlation mapper (SCM) and spectral angle mapper (SAM). The 2D model provided equivalent or relatively better performance than 2.5D models, showing well-matched local noise levels and high spectral similarity compared to the reference (sharper/smoother kernels): MAPD - 2D 1.5%/5.6% (p>0.05), 2.5D <i>N-N</i> 8.5%/7.9% (p<0.05), 2.5D <i>N-1</i> 12.3%/10.9% (p<0.05); mean SCM - 2D 0.97/0.97, 2.5D <i>N-N</i> 0.96/0.97, 2.5D <i>N-1</i> 0.85/0.97; mean SAM - 2D 0.12/0.12, 2.5D <i>N-N</i> 0.14/0.12, 2.5D <i>N-1</i> 0.37/0.12. With tripled model width, the 2.5D <i>N-N</i> outperformed <i>N-1</i>. This indicated 2.5D models need more learning capacity to further enhance 3D noise modeling. Using physics-based prior information, PALETTE can provide high-quality low-dose CT simulation to resemble scanner- and algorithm-specific 3D noise characteristics.

Vol. 13405
Mayo Clinic in Arizona (US)
National Institutes of Health
Openalex Percentile: Top 89%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.