Improving low-contrast liver metastasis detectability in deep-learning CT denoising using adaptive local fusion driven by total uncertainty and predictive mean

Emerging deep-learning-based CT denoising techniques have the potential to improve diagnostic image quality in low-dose CT exams. However, aggressive radiation dose reduction and the intrinsic uncertainty in convolutional neural network (CNN) outputs are detrimental to detecting critical lesions (e.g., liver metastases) in CNN-denoised images. To tackle these issues, we characterized CNN output distribution via total uncertainty (i.e., data + model uncertainties) and predictive mean. Local mean-uncertainty-ratio (MUR) was calculated to detect highly unreliable regions in the denoised images. A MUR-driven adaptive local fusion (ALF) process was developed to adaptively merge local predictive means with the original noisy images, thereby improving image robustness. This process was incorporated into a previously validated deep-learning model observer to quantify liver metastasis detectability, using area under localization receiver operating characteristic curve (LAUC) as the figure-of-merit. For proof-of-concept, the proposed method was established and validated for a ResNet-based CT denoising method. A recent patient abdominal CT dataset was used in validation, involving 3 lesion sizes (7, 9, and 11 mm), 3 lesion contrasts (15, 20, and 25 HU), and 3 dose levels (25%, 50%, and 100% dose). Visual inspection and quantitative analyses were conducted. Statistical significance was tested. Total uncertainty at lesions and liver background generally increased as radiation dose decreased. With fixed dose, lesion-wise MUR showed no dependency on lesion size or contrast, but exhibited large variance across lesion locations (MUR range ~0.7 to 19). Compared to original ResNet-based denoising, the MUR-driven ALF consistently improved lesion detectability in challenging conditions such as lower dose, smaller lesion size, or lower contrast (range of absolute gain in LAUC: 0.04 to 0.1; P-value 0.008). The proposed method has the potential to improve reliability of deep-learning CT denoising and enhance lesion detection.

Authors

Institutions

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3047080
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving low-contrast liver metastasis detectability in deep-learning CT denoising using adaptive local fusion driven by total uncertainty and predictive mean

Hao Gong, Joel G. Fletcher, Scott S. Hsieh, Shravani Kharat et al.
3 links
Medical Imaging Techniques and Applications
article

Improving low-contrast liver metastasis detectability in deep-learning CT denoising using adaptive local fusion driven by total uncertainty and predictive mean

Hao Gong, Joel G. Fletcher, Scott S. Hsieh, Shravani Kharat, Lifeng Yu, Shuai Leng, Cynthia H. McCollough
article en

Abstract

Emerging deep-learning-based CT denoising techniques have the potential to improve diagnostic image quality in low-dose CT exams. However, aggressive radiation dose reduction and the intrinsic uncertainty in convolutional neural network (CNN) outputs are detrimental to detecting critical lesions (e.g., liver metastases) in CNN-denoised images. To tackle these issues, we characterized CNN output distribution via total uncertainty (i.e., data + model uncertainties) and predictive mean. Local mean-uncertainty-ratio (MUR) was calculated to detect highly unreliable regions in the denoised images. A MUR-driven adaptive local fusion (ALF) process was developed to adaptively merge local predictive means with the original noisy images, thereby improving image robustness. This process was incorporated into a previously validated deep-learning model observer to quantify liver metastasis detectability, using area under localization receiver operating characteristic curve (LAUC) as the figure-of-merit. For proof-of-concept, the proposed method was established and validated for a ResNet-based CT denoising method. A recent patient abdominal CT dataset was used in validation, involving 3 lesion sizes (7, 9, and 11 mm), 3 lesion contrasts (15, 20, and 25 HU), and 3 dose levels (25%, 50%, and 100% dose). Visual inspection and quantitative analyses were conducted. Statistical significance was tested. Total uncertainty at lesions and liver background generally increased as radiation dose decreased. With fixed dose, lesion-wise MUR showed no dependency on lesion size or contrast, but exhibited large variance across lesion locations (MUR range ~0.7 to 19). Compared to original ResNet-based denoising, the MUR-driven ALF consistently improved lesion detectability in challenging conditions such as lower dose, smaller lesion size, or lower contrast (range of absolute gain in LAUC: 0.04 to 0.1; P-value 0.008). The proposed method has the potential to improve reliability of deep-learning CT denoising and enhance lesion detection.

Vol. 13405
Mayo Clinic (US), Mayo Clinic in Arizona (US), Mayo Clinic in Florida (US)
National Institutes of Health
Climate action
Openalex Percentile: Top 89%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.