The impact of noise texture on a deep learning denoising model for high-resolution cardiac EID-CT

A convolutional neural network was trained for denoising high-resolution (HR) energy-integrating detector (EID) cardiac CT images. To supervise the training, noise-only images were estimated from patient images using two different methods: Subtraction of low and high iterative reconstruction (IR) strength reconstructions; subtraction of adjacent image slices with the same IR strength. After training, the models were applied to independent HR cardiac EID-CT images and compared to HR photon-counting detector (PCD)-CT images. Models trained with either noise-image generation method reduced noise in HR EID-CT images by 74-79% to achieve comparable noise to HR PCD-CT images. However, the model trained on subtraction of low and high IR images resulted in undesirable salt-and-pepper noise texture and CT number bias. The model trained on adjacent slice subtraction images had more natural texture and no significant bias. Both models preserved spatial resolution of the inputs and did not alter anatomical structures.

Authors

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3047056
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of noise texture on a deep learning denoising model for high-resolution cardiac EID-CT

Kevin Treb, Shaojie Chang, Shuai Leng, Cynthia H. McCollough et al.
2 links
Advanced X-ray and CT Imaging
article

The impact of noise texture on a deep learning denoising model for high-resolution cardiac EID-CT

Kevin Treb, Shaojie Chang, Shuai Leng, Cynthia H. McCollough, J. Wallis Marsh
article en

Abstract

A convolutional neural network was trained for denoising high-resolution (HR) energy-integrating detector (EID) cardiac CT images. To supervise the training, noise-only images were estimated from patient images using two different methods: Subtraction of low and high iterative reconstruction (IR) strength reconstructions; subtraction of adjacent image slices with the same IR strength. After training, the models were applied to independent HR cardiac EID-CT images and compared to HR photon-counting detector (PCD)-CT images. Models trained with either noise-image generation method reduced noise in HR EID-CT images by 74-79% to achieve comparable noise to HR PCD-CT images. However, the model trained on subtraction of low and high IR images resulted in undesirable salt-and-pepper noise texture and CT number bias. The model trained on adjacent slice subtraction images had more natural texture and no significant bias. Both models preserved spatial resolution of the inputs and did not alter anatomical structures.

Climate action
Openalex Percentile: Top 93%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.