Synthetic mask energy subtraction angiography: phantom study

Angioplasty is an interventional procedure for blood vessel stenosis in patients with vascular diseases. Digital subtraction angiography (DSA) is the gold standard imaging technique for imaging neurological and extremity vasculature. DSA enhances visibility of contrasted vessels by removing the visibility of the background structures (bone and tissue) using a pre- and post- iodine injection image subtraction. Due to the time delay between the mask and contrast image, DSA is not feasible for cardiac imaging due to significant tissue motion (lungs, heart muscles). Energy subtraction angiography (ESA) acquires two images in rapid succession using a kV-switching generator at a low and high energy, removing the need for a pre-injection image. The difference in attenuation coefficients as a function of changing energy allows for tissue suppression using a weighted log subtraction. A phantom study using an anthropomorphic chest phantom and custom 3D printed vessel was performed. The vessel was manually shifted to simulate cardiac motion, and a set of consecutive ESA images were acquired using parameters optimized in a theoretical simulation. The simulation optimized the iodine signal to noise ratio (SNR) using a stationary attenuation filter, as only a 5-15% decrease in the SNR was seen compared to using a complex rotating filter. An anti-correlated noise reduction algorithm was applied to all ESA images to compensate for the loss in iodine SNR. By evaluating the motion of the vessel across the ESA image frames, a synthetic mask image was created using an algorithm that evaluated the change in attenuation in individual pixels across the image set. The algorithm selected out the pixels that the vessel had moved out of, and reconstructs an image using only the pixels not containing the iodinated vessel. Once subtracted from an ESA image, a DSA-like image of just the vessel remains, resembling the gold standard imaging technique used for neurological imaging, in a simulated cardiac scenario. The proposed technique has the potential to yield diagnostic images of complex vasculature with fewer exposures, thereby reducing dose to the patient and procedure length.

Authors

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3047297
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthetic mask energy subtraction angiography: phantom study

Ian A. Cunningham, Haechan J. Yang, Michael R. Ward, Lisa M. Garland
Advanced X-ray and CT Imaging
article

Synthetic mask energy subtraction angiography: phantom study

Ian A. Cunningham, Haechan J. Yang, Michael R. Ward, Lisa M. Garland
article en

Abstract

Angioplasty is an interventional procedure for blood vessel stenosis in patients with vascular diseases. Digital subtraction angiography (DSA) is the gold standard imaging technique for imaging neurological and extremity vasculature. DSA enhances visibility of contrasted vessels by removing the visibility of the background structures (bone and tissue) using a pre- and post- iodine injection image subtraction. Due to the time delay between the mask and contrast image, DSA is not feasible for cardiac imaging due to significant tissue motion (lungs, heart muscles). Energy subtraction angiography (ESA) acquires two images in rapid succession using a kV-switching generator at a low and high energy, removing the need for a pre-injection image. The difference in attenuation coefficients as a function of changing energy allows for tissue suppression using a weighted log subtraction. A phantom study using an anthropomorphic chest phantom and custom 3D printed vessel was performed. The vessel was manually shifted to simulate cardiac motion, and a set of consecutive ESA images were acquired using parameters optimized in a theoretical simulation. The simulation optimized the iodine signal to noise ratio (SNR) using a stationary attenuation filter, as only a 5-15% decrease in the SNR was seen compared to using a complex rotating filter. An anti-correlated noise reduction algorithm was applied to all ESA images to compensate for the loss in iodine SNR. By evaluating the motion of the vessel across the ESA image frames, a synthetic mask image was created using an algorithm that evaluated the change in attenuation in individual pixels across the image set. The algorithm selected out the pixels that the vessel had moved out of, and reconstructs an image using only the pixels not containing the iodinated vessel. Once subtracted from an ESA image, a DSA-like image of just the vessel remains, resembling the gold standard imaging technique used for neurological imaging, in a simulated cardiac scenario. The proposed technique has the potential to yield diagnostic images of complex vasculature with fewer exposures, thereby reducing dose to the patient and procedure length.

Affordable and clean energy
Openalex Percentile: Top 93%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.