On the performance of a stacked dual-layer flat-panel detector

In radiography, dual-layer detectors are commonly used to separate objects such as bones and tissues. Additionally, the use of dual-layer detectors allows for X-ray images with improved detection quantum efficiency (DQE) performance. In this paper, we observe the DQE performance of a dual-layer detector, in which two flat-panel detector layers are stacked with a minimal distance between the layers. To design an aligned dual-layer detector (ADD), a subpixel registration based on an amplitude response is employed between the images acquired from the upper and lower layers, and the lower image is translated based on the Fourier shift theorem. The performance of ADD is evaluated by observing a convex combination of the upper and lower images in terms of the modulation transfer function (MTF), noise power spectrum, and DQE. We also observe the contrast performance by using a contrast-detail phantom of CDRAD. ADD can obtain a better performance than that of the single upper detector layer especially at relatively high x-ray tube voltages. For example, under the RQA 9 condition, ADD can achieve a DQE of 75:0% compared to 56:1% for a single layer detector at zero frequency. Additionally, the problem of non-uniform MTF and DQE across the pixels of the entire detector and the artifact problem caused by the antiscatter grid are also discussed.

Authors

Institutions

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3046572
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the performance of a stacked dual-layer flat-panel detector

Choul Woo Shin, Ilwoong Choi, Hyun-Jong Kim, Young Bok Kim et al.
1 citations
Building Energy and Comfort Optimization
1.01
article

On the performance of a stacked dual-layer flat-panel detector

Choul Woo Shin, Ilwoong Choi, Hyun-Jong Kim, Young Bok Kim, Dong Sik Kim, Dayeon Lee, Young Min Jeon
article en
1 citations

Abstract

In radiography, dual-layer detectors are commonly used to separate objects such as bones and tissues. Additionally, the use of dual-layer detectors allows for X-ray images with improved detection quantum efficiency (DQE) performance. In this paper, we observe the DQE performance of a dual-layer detector, in which two flat-panel detector layers are stacked with a minimal distance between the layers. To design an aligned dual-layer detector (ADD), a subpixel registration based on an amplitude response is employed between the images acquired from the upper and lower layers, and the lower image is translated based on the Fourier shift theorem. The performance of ADD is evaluated by observing a convex combination of the upper and lower images in terms of the modulation transfer function (MTF), noise power spectrum, and DQE. We also observe the contrast performance by using a contrast-detail phantom of CDRAD. ADD can obtain a better performance than that of the single upper detector layer especially at relatively high x-ray tube voltages. For example, under the RQA 9 condition, ADD can achieve a DQE of 75:0% compared to 56:1% for a single layer detector at zero frequency. Additionally, the problem of non-uniform MTF and DQE across the pixels of the entire detector and the artifact problem caused by the antiscatter grid are also discussed.

Vatech (South Korea) (KR), Hankuk University of Foreign Studies (KR)
Affordable and clean energy
Openalex Percentile: Top 26%
Building Energy and Comfort Optimization
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.