Rotating anode x-ray tube technology at the limit

The input power density of rotating anode x-ray sources and hence the spatial image resolution of the x-ray system must be fundamentally restricted due to the erosion of anode material. The efficacy of computed tomography would benefit from much smaller x-ray focal spots with equal or increased photon output. A switch to carbon fiber reinforced rotor members that may enable higher rotor velocity has been suggested, or increasing the tube voltage for deeper implantation of electronic input power. Alternatively, we are proposing a new fast moving tungsten microparticle target that avoids focal track erosion, offers high mass heat capacity from increased temperature swing and reduced material residence time in the electron beam. This novel technology concept promises to eliminate the bottleneck and allow for an order of magnitude improvement of the focal spot input power density. However, before investing in implementation the ultimate limitations of current technology should be better known than currently. To gain knowledge, we improved the modeling of electron transport and target erosion of rotary anodes. We infer a criticality parameter that enables predicting the risk of anode erosion for a wide range of technique factors and focal spot sizes based on a few reference life cycle tests. In conclusion, despite the deficits of assumptions made in the classic Müller-Oosterkamp theory that ignores tube voltage, the derived specifications of commercial x-ray tubes are justified. Limited by anode erosion, the gain of permitted power density with increasing tube voltage is smaller than predicted by some alternative volume heating models. We further discovered the necessity to introduce a correction for calculations of the applied patient x-ray dose and pointed to the related error in the standards for radiation safety.

Authors

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3044261
Primary Topic
Hydrogen embrittlement and corrosion behaviors in metals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rotating anode x-ray tube technology at the limit

Christopher Hulme-Smith, P. Tolias, Mats Danielsson, Rolf Behling
Hydrogen embrittlement and corrosion behaviors in metals
article

Rotating anode x-ray tube technology at the limit

Christopher Hulme-Smith, P. Tolias, Mats Danielsson, Rolf Behling
article en

Abstract

The input power density of rotating anode x-ray sources and hence the spatial image resolution of the x-ray system must be fundamentally restricted due to the erosion of anode material. The efficacy of computed tomography would benefit from much smaller x-ray focal spots with equal or increased photon output. A switch to carbon fiber reinforced rotor members that may enable higher rotor velocity has been suggested, or increasing the tube voltage for deeper implantation of electronic input power. Alternatively, we are proposing a new fast moving tungsten microparticle target that avoids focal track erosion, offers high mass heat capacity from increased temperature swing and reduced material residence time in the electron beam. This novel technology concept promises to eliminate the bottleneck and allow for an order of magnitude improvement of the focal spot input power density. However, before investing in implementation the ultimate limitations of current technology should be better known than currently. To gain knowledge, we improved the modeling of electron transport and target erosion of rotary anodes. We infer a criticality parameter that enables predicting the risk of anode erosion for a wide range of technique factors and focal spot sizes based on a few reference life cycle tests. In conclusion, despite the deficits of assumptions made in the classic Müller-Oosterkamp theory that ignores tube voltage, the derived specifications of commercial x-ray tubes are justified. Limited by anode erosion, the gain of permitted power density with increasing tube voltage is smaller than predicted by some alternative volume heating models. We further discovered the necessity to introduce a correction for calculations of the applied patient x-ray dose and pointed to the related error in the standards for radiation safety.

Affordable and clean energy
Openalex Percentile: Top 96%
Hydrogen embrittlement and corrosion behaviors in metals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.