High-fidelity prefiltration using a double bowtie design for quantitative low-dose pediatric spectral CT imaging

In parallel with efforts to minimize radiation exposure in pediatric patients, computed tomography (CT) remains the primary imaging modality for children, owing to its rapid scan times and excellent spatial resolution. Spectral CT, which enables the generation of virtual monoenergetic images (VMIs), can improve image contrast and reduce artifacts without increasing radiation dose. However, most CT systems are optimized for adult-sized patients, posing challenges in pediatric imaging and leading to missed opportunities to for example improve spectral separability—a crucial factor for enhanced image quality and accurate material decomposition. This study introduces a novel “double bowtie” filtration design that integrates traditional Teflon bowtie filters with K-edge material filtration to enhance spectral signal-to-noise ratio (SNR) in VMIs for pediatric patients. The double bowtie design involves optimizing the shape of both the Teflon and K-edge materials, as well as adjustments to system parameters, to maximize spectral performance while maintaining radiation doses similar to conventional pediatric CT protocols. Through simulations using pediatric-sized phantoms, significant improvements in SNR were observed with the double bowtie design, particularly when gadolinium was used as the K-edge material. This approach not only improves image quality but also opens the possibility of reducing radiation doses, thus making spectral CT more suitable for pediatric diagnostics. The proposed double bowtie filter can be integrated into existing CT systems without requiring specialized pediatric equipment, potentially improving diagnostic capabilities in spectral CT for pediatric patients. Although further clinical evaluations are necessary, these findings suggest a promising avenue for enhancing pediatric CT imaging while maintaining strict radiation safety standards.

Authors

Institutions

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3046287
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-fidelity prefiltration using a double bowtie design for quantitative low-dose pediatric spectral CT imaging

Olivia F. Sandvold, Ying Ge, Roland Proksa, Amy E. Perkins et al.
1 citations
Advanced X-ray and CT Imaging
0.67
article

High-fidelity prefiltration using a double bowtie design for quantitative low-dose pediatric spectral CT imaging

Olivia F. Sandvold, Ying Ge, Roland Proksa, Amy E. Perkins, Peter B. Noël
article en
1 citations

Abstract

In parallel with efforts to minimize radiation exposure in pediatric patients, computed tomography (CT) remains the primary imaging modality for children, owing to its rapid scan times and excellent spatial resolution. Spectral CT, which enables the generation of virtual monoenergetic images (VMIs), can improve image contrast and reduce artifacts without increasing radiation dose. However, most CT systems are optimized for adult-sized patients, posing challenges in pediatric imaging and leading to missed opportunities to for example improve spectral separability—a crucial factor for enhanced image quality and accurate material decomposition. This study introduces a novel “double bowtie” filtration design that integrates traditional Teflon bowtie filters with K-edge material filtration to enhance spectral signal-to-noise ratio (SNR) in VMIs for pediatric patients. The double bowtie design involves optimizing the shape of both the Teflon and K-edge materials, as well as adjustments to system parameters, to maximize spectral performance while maintaining radiation doses similar to conventional pediatric CT protocols. Through simulations using pediatric-sized phantoms, significant improvements in SNR were observed with the double bowtie design, particularly when gadolinium was used as the K-edge material. This approach not only improves image quality but also opens the possibility of reducing radiation doses, thus making spectral CT more suitable for pediatric diagnostics. The proposed double bowtie filter can be integrated into existing CT systems without requiring specialized pediatric equipment, potentially improving diagnostic capabilities in spectral CT for pediatric patients. Although further clinical evaluations are necessary, these findings suggest a promising avenue for enhancing pediatric CT imaging while maintaining strict radiation safety standards.

California University of Pennsylvania (US), Philips (United States) (US)
Openalex Percentile: Top 33%
Advanced X-ray and CT Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.