Reliability of Exhaled Acetone and Isoprene in Healthy Active Adult Responses to Sub-maximal Treadmill Exercise: A Pilot Study
Abstract This study investigates the test–retest reliability of exhaled acetone and isoprene as potential biomarkers for monitoring exercise-induced physiological changes. Ten healthy active males (age 22.7 ± 3.7 years, height 182.4 ± 6.8 cm, body mass 80.12 ± 8.5 kg, body mass index 24.0 ± 1.4 kg/m 2 , VO 2peak 55 ± 4 mL/kg/min, physical activity 322 min/week) provided baseline measures before undergoing a VO 2peak test and two treadmill exercise trials, interspersed by 7-days’ rest. Treadmill exercise consisted of 20 min at 80% of VO 2peak speed. Breath samples were collected before exercise, 10 min, and 24 h after exercise, using glass containers and solid-phase microextraction fibres, and analysed by gas-chromatography mass-spectrometry. Exhaled acetone exhibited poor internal consistency (Cronbach’s α = − 0.184) and agreement ( ICC = − 0.096 [− 0.836–0.607], P = 0.592) with a high technical error (TE = 2.38 × 10 6 ) and coefficient of variation ( CV = 90%). In contrast, exhaled isoprene provided satisfactory internal consistency (Cronbach’s α 0.817) and good agreement ( ICC = 0.699, P = 0.009), with a lower technical error (TE = 1.24 × 10 6 ) and coefficient of variation ( CV = 28%). Quadratic regression showed a decrease in isoprene 10 min after exercise during trial 1 ( P < 0.01) and trial 2 ( P < 0.05) and returned to baseline levels after 24 h. While acetone’s reliability was questionable, isoprene levels following 20 min of submaximal treadmill exercise are notably reproducible among healthy active males.
Authors
- Jack Harvey (ORCID: https://orcid.org/0000-0001-6927-6580)
- Declan Hennessy (ORCID: https://orcid.org/0000-0003-0924-0601)
- B O’Brien (ORCID: https://orcid.org/0000-0002-6371-1796)
- Mark A. Myers (ORCID: https://orcid.org/0000-0003-1156-4795)
- Matthew P. Wallen (ORCID: https://orcid.org/0000-0002-2201-7933)
- Leo R. Bell (ORCID: https://orcid.org/0000-0002-4574-6397)
- Ryan Worn (ORCID: https://orcid.org/0000-0002-5923-5424)
- Gregory Davis (ORCID: https://orcid.org/0000-0002-5008-1158)
Institutions
- Deakin University (AU)
- Flinders University (AU)
- Melbourne Health (AU)
- Swinburne University of Technology (AU)
Publication Details
- Journal
- Journal of Science in Sport and Exercise
- Published
- 2025-04-08
- DOI
- https://doi.org/10.1007/s42978-025-00327-x
- Primary Topic
- Advanced Chemical Sensor Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Australian Government
- Federation University Australia