Reliability of Exhaled Acetone and Isoprene in Healthy Active Adult Responses to Sub-maximal Treadmill Exercise: A Pilot Study

Abstract This study investigates the test–retest reliability of exhaled acetone and isoprene as potential biomarkers for monitoring exercise-induced physiological changes. Ten healthy active males (age 22.7 ± 3.7 years, height 182.4 ± 6.8 cm, body mass 80.12 ± 8.5 kg, body mass index 24.0 ± 1.4 kg/m 2 , VO 2peak 55 ± 4 mL/kg/min, physical activity 322 min/week) provided baseline measures before undergoing a VO 2peak test and two treadmill exercise trials, interspersed by 7-days’ rest. Treadmill exercise consisted of 20 min at 80% of VO 2peak speed. Breath samples were collected before exercise, 10 min, and 24 h after exercise, using glass containers and solid-phase microextraction fibres, and analysed by gas-chromatography mass-spectrometry. Exhaled acetone exhibited poor internal consistency (Cronbach’s α = − 0.184) and agreement ( ICC = − 0.096 [− 0.836–0.607], P = 0.592) with a high technical error (TE = 2.38 × 10 6 ) and coefficient of variation ( CV = 90%). In contrast, exhaled isoprene provided satisfactory internal consistency (Cronbach’s α 0.817) and good agreement ( ICC = 0.699, P = 0.009), with a lower technical error (TE = 1.24 × 10 6 ) and coefficient of variation ( CV = 28%). Quadratic regression showed a decrease in isoprene 10 min after exercise during trial 1 ( P < 0.01) and trial 2 ( P < 0.05) and returned to baseline levels after 24 h. While acetone’s reliability was questionable, isoprene levels following 20 min of submaximal treadmill exercise are notably reproducible among healthy active males.

Authors

Institutions

Publication Details

Journal
Journal of Science in Sport and Exercise
Published
2025-04-08
DOI
https://doi.org/10.1007/s42978-025-00327-x
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of Exhaled Acetone and Isoprene in Healthy Active Adult Responses to Sub-maximal Treadmill Exercise: A Pilot Study

Jack Harvey, Declan Hennessy, B O’Brien, Mark A. Myers et al.
Journal of Science in Sport and Exercise
Advanced Chemical Sensor Technologies
article

Reliability of Exhaled Acetone and Isoprene in Healthy Active Adult Responses to Sub-maximal Treadmill Exercise: A Pilot Study

Jack Harvey, Declan Hennessy, B O’Brien, Mark A. Myers, Matthew P. Wallen, Leo R. Bell, Ryan Worn, Gregory Davis
article en

Abstract

Abstract This study investigates the test–retest reliability of exhaled acetone and isoprene as potential biomarkers for monitoring exercise-induced physiological changes. Ten healthy active males (age 22.7 ± 3.7 years, height 182.4 ± 6.8 cm, body mass 80.12 ± 8.5 kg, body mass index 24.0 ± 1.4 kg/m 2 , VO 2peak 55 ± 4 mL/kg/min, physical activity 322 min/week) provided baseline measures before undergoing a VO 2peak test and two treadmill exercise trials, interspersed by 7-days’ rest. Treadmill exercise consisted of 20 min at 80% of VO 2peak speed. Breath samples were collected before exercise, 10 min, and 24 h after exercise, using glass containers and solid-phase microextraction fibres, and analysed by gas-chromatography mass-spectrometry. Exhaled acetone exhibited poor internal consistency (Cronbach’s α = − 0.184) and agreement ( ICC = − 0.096 [− 0.836–0.607], P = 0.592) with a high technical error (TE = 2.38 × 10 6 ) and coefficient of variation ( CV = 90%). In contrast, exhaled isoprene provided satisfactory internal consistency (Cronbach’s α 0.817) and good agreement ( ICC = 0.699, P = 0.009), with a lower technical error (TE = 1.24 × 10 6 ) and coefficient of variation ( CV = 28%). Quadratic regression showed a decrease in isoprene 10 min after exercise during trial 1 ( P < 0.01) and trial 2 ( P < 0.05) and returned to baseline levels after 24 h. While acetone’s reliability was questionable, isoprene levels following 20 min of submaximal treadmill exercise are notably reproducible among healthy active males.

Journal of Science in Sport and Exercise
Deakin University (AU), Flinders University (AU), Melbourne Health (AU), Swinburne University of Technology (AU)
Australian Government, Federation University Australia
Openalex Percentile: Top 93%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.