Contrast-guided virtual monoenergetic image synthesis via adversarial learning for coronary CT angiography using photon counting detector CT

Coronary CT angiography (cCTA) is a non-invasive diagnostic test for coronary artery disease (CAD) that often faces challenges with dense calcifications and stents due to blooming artifacts, leading to stenosis overestimation. Virtual monoenergetic images (VMIs) from photon counting detector CT (PCD-CT) provide distinct clinical benefits. Lower keV VMIs enhance iodine and bone contrasts but struggle with blooming artifacts, while higher keV VMIs effectively reduce beam hardening, blooming, and metal artifacts but diminish contrast, presenting a trade-off among different keV levels. To address this, we introduce a contrast-guided virtual monoenergetic image synthesis framework (CITRINE) utilizing adversarial learning to synthesize images by integrating beneficial spectral characteristics from various keV levels. In this study, CITRINE is trained and validated with cardiac PCD-CT images using 100 keV and 70 keV VMIs as examples, showcasing its ability to synthesize images that combine the reduced blooming artifacts of 100 keV VMIs with the high contrast-to-noise features of 70 keV VMIs. CITRINE's performance was evaluated on three patient cCTA cases quantitatively and qualitatively in terms of image quality and assessments of percent diameter luminal stenosis. The synthesized images showed reduced blooming artifacts, similar to those observed at 100 keV VMI, and exhibited high iodine contrast in the coronary lumen, comparable to that of 70 keV VMI. Notably, compared to the original 70 keV VMI, CITRINE images achieved approximately 25% reduction in percent diameter stenosis while maintaining consistent contrast levels. These results confirm CITRINE's effectiveness in improving diagnostic accuracy and efficiency in cCTA by leveraging the full potential of multi-energy and PCD-CT technologies.

Authors

Institutions

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1117/12.3047277
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contrast-guided virtual monoenergetic image synthesis via adversarial learning for coronary CT angiography using photon counting detector CT

Hao Gong, Shaojie Chang, Lifeng Yu, Michael K. Wilson et al.
1 citations
Advanced X-ray and CT Imaging
0.67
article

Contrast-guided virtual monoenergetic image synthesis via adversarial learning for coronary CT angiography using photon counting detector CT

Hao Gong, Shaojie Chang, Lifeng Yu, Michael K. Wilson, Cynthia H. McCollough, Emily K. Koons, Scott S. Hsieh, Shuai Leng
article en
1 citations

Abstract

Coronary CT angiography (cCTA) is a non-invasive diagnostic test for coronary artery disease (CAD) that often faces challenges with dense calcifications and stents due to blooming artifacts, leading to stenosis overestimation. Virtual monoenergetic images (VMIs) from photon counting detector CT (PCD-CT) provide distinct clinical benefits. Lower keV VMIs enhance iodine and bone contrasts but struggle with blooming artifacts, while higher keV VMIs effectively reduce beam hardening, blooming, and metal artifacts but diminish contrast, presenting a trade-off among different keV levels. To address this, we introduce a contrast-guided virtual monoenergetic image synthesis framework (CITRINE) utilizing adversarial learning to synthesize images by integrating beneficial spectral characteristics from various keV levels. In this study, CITRINE is trained and validated with cardiac PCD-CT images using 100 keV and 70 keV VMIs as examples, showcasing its ability to synthesize images that combine the reduced blooming artifacts of 100 keV VMIs with the high contrast-to-noise features of 70 keV VMIs. CITRINE's performance was evaluated on three patient cCTA cases quantitatively and qualitatively in terms of image quality and assessments of percent diameter luminal stenosis. The synthesized images showed reduced blooming artifacts, similar to those observed at 100 keV VMI, and exhibited high iodine contrast in the coronary lumen, comparable to that of 70 keV VMI. Notably, compared to the original 70 keV VMI, CITRINE images achieved approximately 25% reduction in percent diameter stenosis while maintaining consistent contrast levels. These results confirm CITRINE's effectiveness in improving diagnostic accuracy and efficiency in cCTA by leveraging the full potential of multi-energy and PCD-CT technologies.

Vol. 13405
Mayo Clinic in Arizona (US)
National Institutes of Health
Openalex Percentile: Top 33%
Advanced X-ray and CT Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.