Fast response cathodic electrochemiluminescence sensor based on closed bipolar electrode for point-of-care blood glucose testing

Glucose detection is vital for managing diabetes, monitoring metabolic disorders, and developing advanced biosensors. Electrochemical methods are widely used for glucose detection due to their sensitivity, portability, and low cost. However, these methods also have several limitations, such as interference from non-specific molecules, fouling of electrodes, and enzyme stability. Herein, to avoid external interference, we report a fast response cathodic electrochemiluminescence (ECL) glucose biosensor using a closed bipolar electrode (BPE) system with two separate cells (reporting cell and sensing cell). In this platform, Tris(2,2'-bipyridyl) ruthenium and K<sub>2</sub>S<sub>2</sub>O<sub>8</sub> were used as the luminophore and co-reagent, respectively, to generate the cathodic ECL in the reporting cell, and a commercial test strip modified with GO<sub>x</sub> (glucose oxidase) and mediator served as the BPE anode to detect glucose in the sensing cell. The developed technique was able to determine glucose with a good correlation in the quantification of glucose in human serum samples with a fast response under a low potential, which avoided side reactions and was comparable to the commercial blood glucose meter. In addition, the sensing mechanism and working principle have been thoroughly studied, with the detailed discussion of the effect of oxygen and acetonitrile in influencing the ECL generation. Using this platform, glucose in the buffer was successfully quantified up to 18 mM, achieving a limit of detection of 3.8 mM and a linear concentration range between 4 and 12 mM. This electrochemical technique offers a simple and cost-effective strategy for point-of-care blood glucose testing without external interference, thereby opening up emerging opportunities in a broad range of sensing applications.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2025-04-08
DOI
https://doi.org/10.1016/j.talanta.2025.128104
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast response cathodic electrochemiluminescence sensor based on closed bipolar electrode for point-of-care blood glucose testing

Masoud A. Mehrgardi, Sanjun Fan, Curtis Shannon, Chungkuk Jin et al.
Talanta
Advanced biosensing and bioanalysis techniques
article

Fast response cathodic electrochemiluminescence sensor based on closed bipolar electrode for point-of-care blood glucose testing

Masoud A. Mehrgardi, Sanjun Fan, Curtis Shannon, Chungkuk Jin, Buhua Wang, Songyan Yu, Md Akteruzzaman
article en

Abstract

Glucose detection is vital for managing diabetes, monitoring metabolic disorders, and developing advanced biosensors. Electrochemical methods are widely used for glucose detection due to their sensitivity, portability, and low cost. However, these methods also have several limitations, such as interference from non-specific molecules, fouling of electrodes, and enzyme stability. Herein, to avoid external interference, we report a fast response cathodic electrochemiluminescence (ECL) glucose biosensor using a closed bipolar electrode (BPE) system with two separate cells (reporting cell and sensing cell). In this platform, Tris(2,2'-bipyridyl) ruthenium and K<sub>2</sub>S<sub>2</sub>O<sub>8</sub> were used as the luminophore and co-reagent, respectively, to generate the cathodic ECL in the reporting cell, and a commercial test strip modified with GO<sub>x</sub> (glucose oxidase) and mediator served as the BPE anode to detect glucose in the sensing cell. The developed technique was able to determine glucose with a good correlation in the quantification of glucose in human serum samples with a fast response under a low potential, which avoided side reactions and was comparable to the commercial blood glucose meter. In addition, the sensing mechanism and working principle have been thoroughly studied, with the detailed discussion of the effect of oxygen and acetonitrile in influencing the ECL generation. Using this platform, glucose in the buffer was successfully quantified up to 18 mM, achieving a limit of detection of 3.8 mM and a linear concentration range between 4 and 12 mM. This electrochemical technique offers a simple and cost-effective strategy for point-of-care blood glucose testing without external interference, thereby opening up emerging opportunities in a broad range of sensing applications.

TalantaVol. 293
Peking University (CN), Hainan University (CN), Purdue University West Lafayette (US), University of Isfahan (IR), Peking University School and Hospital of Stomatology (CN), The Ohio State University (US), Auburn University (US)
Auburn University, China Academy of Space Technology, Beijing Association for Science and Technology
Zero hunger
Openalex Percentile: Top 94%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.