Multi-Channel Multi-Protocol Quantum Key Distribution System for Secure Image Transmission in Healthcare

Quantum key distribution (QKD) is a viable technique for safeguarding image transmission against numerous attacks. To address the limitations of existing methods in securing electronic medical records, we have explored an encryption technique using a set of real-time medical images along with existing standard images using QKD protocols including BB84 (Bennett-Brassard 1984), CASCADE (Cascading Error Correction Algorithm for Data Exchange), and differential-phase-shift (DPS) under the fiber-based (OFC) and free-space (FSO) channels. It utilizes the quantum bit-plane representation of the Real Ket (QBRK) model and a logistic chaotic system with XOR operation. The performance of the developed framework is tested via visual illustration and 11 different quantitative assessments. The average entropy of the scrambled image for the medical source image is 7.9896, which is quite near to the optimum value of 8. The <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">UACI</i> (Unified Averaged Changed Intensity) and the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">NPCR</i> (Number of Pixels Change Rate) metrics values lie between 33.7879 to 33.9711 and 99.6014 to 99.8000 for the FSO channel. The BB84 QKD protocol achieves a QBER (Quantum Bit Error Rate) of 0.0028 for an FSO channel with DCR (Dark Count Rate), which improves to 0.0012 when DCR is ignored for a 10 km link range. In addition, we analyzed and compared the effect of OFC on system output as the quantum channel. From several experiments, it is observed that the BB84 provides better results against CASCADE and DPS. The proposed work is validated using the Optisystem 15.1 software under FSO and for OFC.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3558294
Citations
19
Primary Topic
Quantum-Dot Cellular Automata
Type
article
Field-Weighted Citation Impact
28.58
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Channel Multi-Protocol Quantum Key Distribution System for Secure Image Transmission in Healthcare

Bibhu Prasad, Chittaranjan Nayak, Gajanan Uttam Patil, Priyadarsan Parida et al.
19 citations
IEEE Access
Quantum-Dot Cellular Automata
28.58
article

Multi-Channel Multi-Protocol Quantum Key Distribution System for Secure Image Transmission in Healthcare

Bibhu Prasad, Chittaranjan Nayak, Gajanan Uttam Patil, Priyadarsan Parida, Nawaf Ali, Tarek Khalifa, Bandana Mallick, Manoj Kumar Panda
article en
19 citations

Abstract

Quantum key distribution (QKD) is a viable technique for safeguarding image transmission against numerous attacks. To address the limitations of existing methods in securing electronic medical records, we have explored an encryption technique using a set of real-time medical images along with existing standard images using QKD protocols including BB84 (Bennett-Brassard 1984), CASCADE (Cascading Error Correction Algorithm for Data Exchange), and differential-phase-shift (DPS) under the fiber-based (OFC) and free-space (FSO) channels. It utilizes the quantum bit-plane representation of the Real Ket (QBRK) model and a logistic chaotic system with XOR operation. The performance of the developed framework is tested via visual illustration and 11 different quantitative assessments. The average entropy of the scrambled image for the medical source image is 7.9896, which is quite near to the optimum value of 8. The <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">UACI</i> (Unified Averaged Changed Intensity) and the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">NPCR</i> (Number of Pixels Change Rate) metrics values lie between 33.7879 to 33.9711 and 99.6014 to 99.8000 for the FSO channel. The BB84 QKD protocol achieves a QBER (Quantum Bit Error Rate) of 0.0028 for an FSO channel with DCR (Dark Count Rate), which improves to 0.0012 when DCR is ignored for a 10 km link range. In addition, we analyzed and compared the effect of OFC on system output as the quantum channel. From several experiments, it is observed that the BB84 provides better results against CASCADE and DPS. The proposed work is validated using the Optisystem 15.1 software under FSO and for OFC.

IEEE AccessVol. 13
Dr. Babasaheb Ambedkar Technological University (IN), American University of the Middle East (KW), GIET University (IN), Vellore Institute of Technology University (IN)
Openalex Percentile: Top 0%
Quantum-Dot Cellular Automata
28.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.