Trace Chromium Ion Detection Based on 4-Mercaptobenzoic Acid Functionalized Plasmonic Fiber-Optic Spectral Combs

High sensitivity chromium ions (Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup>) sensor was developed based on the combination of gold nanomaterials-coated tilted fiber Bragg grating (TFBG) and 4-mercaptobenzoic acid (4-MBA). The TFBG was first deposited with a 50 nm gold film to excite sensitive surface plasmonic resonance (SPR) spectral combs and then functionalized with a 4-MBA layer that is available for specifically capturing Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> ions. To further enhance the SPR-Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> interaction, additional gold nanoparticles (AuNPs)-4-MBA composite was prepared and bonded with the Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> captured by the TFBG. Thus, the SPR response to the capture of Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> and the sensing performance were greatly enhanced. Experimental results show that the sensor exhibits a high sensitivity of 1.23 dB/log(nM) for Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> with a detection limit of 0.04 nM, which is lower than that of the current similar optical Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> detection sensor by one order of magnitude.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-08
DOI
https://doi.org/10.1109/jsen.2025.3557198
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trace Chromium Ion Detection Based on 4-Mercaptobenzoic Acid Functionalized Plasmonic Fiber-Optic Spectral Combs

Wenbo Sui, Ziqiao Ren, Ruotong Tian, Zhihong Li et al.
1 citations
IEEE Sensors Journal
Analytical Chemistry and Sensors
0.74
article

Trace Chromium Ion Detection Based on 4-Mercaptobenzoic Acid Functionalized Plasmonic Fiber-Optic Spectral Combs

Wenbo Sui, Ziqiao Ren, Ruotong Tian, Zhihong Li, Xijie Feng, Changyu Shen, Jie Dong, Jun Zhou, Yunjie Cao
article en
1 citations

Abstract

High sensitivity chromium ions (Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup>) sensor was developed based on the combination of gold nanomaterials-coated tilted fiber Bragg grating (TFBG) and 4-mercaptobenzoic acid (4-MBA). The TFBG was first deposited with a 50 nm gold film to excite sensitive surface plasmonic resonance (SPR) spectral combs and then functionalized with a 4-MBA layer that is available for specifically capturing Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> ions. To further enhance the SPR-Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> interaction, additional gold nanoparticles (AuNPs)-4-MBA composite was prepared and bonded with the Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> captured by the TFBG. Thus, the SPR response to the capture of Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> and the sensing performance were greatly enhanced. Experimental results show that the sensor exhibits a high sensitivity of 1.23 dB/log(nM) for Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> with a detection limit of 0.04 nM, which is lower than that of the current similar optical Cr<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> detection sensor by one order of magnitude.

IEEE Sensors JournalVol. 25(11)
Wenzhou University (CN), China Jiliang University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 35%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.