Accuracy of ultrasonic flow-meters on short straight sections of water pipelines

Abstract This paper presents experimental results using the ultrasonic flow-meter “Dnipro-7U” on limited straight sections of water pipelines located before turns and branches. In these pipeline sections, asymmetric water velocity profiles can lead to reduced accuracy in flow measurements using an ultrasonic flow-meter. It was observed that the accuracy of the ultrasonic flow-meter on short straight sections depends on both their length and the water flow regime. The device's passport error is specified as 2%. An additional error (ranging from 0 to 3%) may arise due to variations in the reliability of water flow and supply characteristics input by the operator, deviating from the average values used in the operational calculation algorithm during measurements.

Authors

Institutions

Publication Details

Journal
Pollack Periodica
Published
2025-04-08
DOI
https://doi.org/10.1556/606.2024.01249
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of ultrasonic flow-meters on short straight sections of water pipelines

Ihor Popadiuk, Іван Матлай, Mykola Bosak
Pollack Periodica
Flow Measurement and Analysis
article

Accuracy of ultrasonic flow-meters on short straight sections of water pipelines

Ihor Popadiuk, Іван Матлай, Mykola Bosak
article en

Abstract

Abstract This paper presents experimental results using the ultrasonic flow-meter “Dnipro-7U” on limited straight sections of water pipelines located before turns and branches. In these pipeline sections, asymmetric water velocity profiles can lead to reduced accuracy in flow measurements using an ultrasonic flow-meter. It was observed that the accuracy of the ultrasonic flow-meter on short straight sections depends on both their length and the water flow regime. The device's passport error is specified as 2%. An additional error (ranging from 0 to 3%) may arise due to variations in the reliability of water flow and supply characteristics input by the operator, deviating from the average values used in the operational calculation algorithm during measurements.

Pollack PeriodicaVol. 20(2)
Lviv Polytechnic National University (UA)
Openalex Percentile: Top 92%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of ultrasonic flow-meters on short straight sections of water pipelines — Ihor Popadiuk, Іван Матлай, et al. · Pollack Periodica (2025) | TGRS Research Map | TGRS