Log file‐based quality assurance method for respiratory gating system

Log file analysis revealed precise temporal synchronization, with mean time differences of 0.03 s ± 0.05 s between the planned 25% phase and beam-on, and -0.04 s ± 0.05 s between 75% phase and beam-off. The log-derived beam-on duration (2.61 s ± 0.02 s) closely matched the planned duration (2.66 s ± 0.00 s). Three-month log data showed consistent temporal accuracy, with trigger-on times remaining stable at 2.60 s ± 0.01 s across all measurements. Supporting ion chamber measurements confirmed dosimetric agreement between gating and non-gating modes (difference: 0.05 cGy ± 0.09 cGy) CONCLUSIONS: The proposed log file-based QA method demonstrated high accuracy and reproducibility in assessing respiratory gating performance. This approach provides an efficient, objective method for standardizing QA procedures in respiratory-gated radiation therapy, enhancing treatment accuracy and patient safety.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2025-04-08
DOI
https://doi.org/10.1002/acm2.70101
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Log file‐based quality assurance method for respiratory gating system

Wonjoong Cheon, Kyu Hye Choi, Yunji Seol, Young Kyu Lee et al.
Journal of Applied Clinical Medical Physics
Advanced Radiotherapy Techniques
article

Log file‐based quality assurance method for respiratory gating system

Wonjoong Cheon, Kyu Hye Choi, Yunji Seol, Young Kyu Lee, Hong Qi Tan, C.S. Park, Young‐Nam Kang, Byung Ock Choi
article en

Abstract

Log file analysis revealed precise temporal synchronization, with mean time differences of 0.03 s ± 0.05 s between the planned 25% phase and beam-on, and -0.04 s ± 0.05 s between 75% phase and beam-off. The log-derived beam-on duration (2.61 s ± 0.02 s) closely matched the planned duration (2.66 s ± 0.00 s). Three-month log data showed consistent temporal accuracy, with trigger-on times remaining stable at 2.60 s ± 0.01 s across all measurements. Supporting ion chamber measurements confirmed dosimetric agreement between gating and non-gating modes (difference: 0.05 cGy ± 0.09 cGy) CONCLUSIONS: The proposed log file-based QA method demonstrated high accuracy and reproducibility in assessing respiratory gating performance. This approach provides an efficient, objective method for standardizing QA procedures in respiratory-gated radiation therapy, enhancing treatment accuracy and patient safety.

Journal of Applied Clinical Medical PhysicsVol. 26(7)
Nanyang Technological University (SG), Duke-NUS Medical School (SG), National Cancer Centre Singapore (SG), The Catholic University of Korea Seoul St. Mary's Hospital (KR), Catholic University of Korea (KR)
Catholic University of Korea, Korea Electrotechnology Research Institute, National Research Council of Science and Technology, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 91%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Log file‐based quality assurance method for respiratory gating system — Wonjoong Cheon, Kyu Hye Choi, et al. · Journal of Applied Clinical Medical Physics (2025) | TGRS Research Map | TGRS