Shear Performance of the GFRP Bolt Interface Between the GFRP Profile and UHPC/Concrete Slabs

ABSTRACT In order to assess the feasibility of employing glass fiber reinforced polymer (GFRP) bolts as a corrosion‐resistant solution for composite structures comprising GFRP and ultrahigh‐performance concrete (UHPC), the shear performance of GFRP bolts interface between UHPC and GFRP was investigated through push‐out tests. A total of seventeen GFRP–concrete push‐out specimens were tested, including eleven GFRP–UHPC specimens with a GFRP bolt interface, two GFRP–UHPC specimens with a steel bolt interface, and four GFRP–concrete specimens with a GFRP bolt interface. The experimental parameters included the concrete strength, bolt type, bolt embedment length ( h bolt ), bolt number ( n bolt ), bolt spacing ( s bolt ), and bolt diameter ( d bolt ). The results revealed three failure modes, that is, bolt shear shank failure, concrete failure, and GFRP flange shear failure. Under the same design parameters, the ultimate bearing capacity ( P u ) of GFRP bolt pull‐out specimens is 72.4% and 49% of 4.8 grade steel bolt and 8.8 grade steel bolt pull‐out specimens, respectively. The application of UHPC prevents concrete compression failure. Increasing the d bolt and the n bolt can significantly enhance the P u of the specimen, and the s bolt and h bolt have limited impacts on the P u . The “bilinear” model was proposed to predict the load–slip curve of the GFRP bolt interface between the FRP–UHPC push‐out specimens. Based on the experimental data, a calculation method was proposed to calculate the ultimate shear capacity of the GFRP bolt interface between the FRP‐UHPC specimens.

Authors

Institutions

Publication Details

Journal
The Structural Design of Tall and Special Buildings
Published
2025-04-08
DOI
https://doi.org/10.1002/tal.70019
Citations
1
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shear Performance of the GFRP Bolt Interface Between the GFRP Profile and UHPC/Concrete Slabs

Pu Zhang, Hao Wang, Zimu Wang, Zhao-Xu Yang et al.
1 citations
The Structural Design of Tall and Special Buildings
Structural Behavior of Reinforced Concrete
1.01
article

Shear Performance of the GFRP Bolt Interface Between the GFRP Profile and UHPC/Concrete Slabs

Pu Zhang, Hao Wang, Zimu Wang, Zhao-Xu Yang, Shamim A. Sheikh, Ye Liu, Tao Guan, Xianghua Tao
article en
1 citations

Abstract

ABSTRACT In order to assess the feasibility of employing glass fiber reinforced polymer (GFRP) bolts as a corrosion‐resistant solution for composite structures comprising GFRP and ultrahigh‐performance concrete (UHPC), the shear performance of GFRP bolts interface between UHPC and GFRP was investigated through push‐out tests. A total of seventeen GFRP–concrete push‐out specimens were tested, including eleven GFRP–UHPC specimens with a GFRP bolt interface, two GFRP–UHPC specimens with a steel bolt interface, and four GFRP–concrete specimens with a GFRP bolt interface. The experimental parameters included the concrete strength, bolt type, bolt embedment length ( h bolt ), bolt number ( n bolt ), bolt spacing ( s bolt ), and bolt diameter ( d bolt ). The results revealed three failure modes, that is, bolt shear shank failure, concrete failure, and GFRP flange shear failure. Under the same design parameters, the ultimate bearing capacity ( P u ) of GFRP bolt pull‐out specimens is 72.4% and 49% of 4.8 grade steel bolt and 8.8 grade steel bolt pull‐out specimens, respectively. The application of UHPC prevents concrete compression failure. Increasing the d bolt and the n bolt can significantly enhance the P u of the specimen, and the s bolt and h bolt have limited impacts on the P u . The “bilinear” model was proposed to predict the load–slip curve of the GFRP bolt interface between the FRP–UHPC push‐out specimens. Based on the experimental data, a calculation method was proposed to calculate the ultimate shear capacity of the GFRP bolt interface between the FRP‐UHPC specimens.

The Structural Design of Tall and Special BuildingsVol. 34(5)
Sichuan University (CN), Zhengzhou University (CN), Henan Energy & Chemical Industry Group (China) (CN), China Communications Construction Company (China) (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 26%
Structural Behavior of Reinforced Concrete
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.