Ultrasensitive Peptide-Based Electrochemical Biosensor for Universal Diagnostic of Dengue

Dengue is a neglected disease mainly affecting tropical and subtropical countries. The diagnosis of dengue fever is still a problem since most of it is made from whole or recombinant DENV proteins, which present cross-reactions with other members of the Flavivirus family. Therefore, there is still a huge demand for new diagnostic methods that provide rapid, low-cost, easy-to-use confirmation. Thus, in this study, we developed an affordable electrochemical biosensor for rapidly detecting immunoglobulin G (IgG) serological antibodies in the sera of DENV-infected patients. An identified linear B-cell epitope (DENV/18) specific for DENV 1-4 serotypes recognized by IgG in patient sera was selected as a target molecule after a microarray of peptides using the SPOT-synthesis methodology. After chemical synthesis, the DENV/18-peptide was immobilized on the surface of the working electrode of a commercially available screen-printed gold electrode (SPGE). The capture of DENV-specific IgG allowed for the formation of an immunocomplex that was measured by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) using a potassium ferrocyanide/ferricyanide ([Fe(CN)<sub>6</sub>]<sup>3-/4-</sup>) electrochemical probe. An evaluation of the biosensor's performance showed a detection limit of 100 µg mL<sup>-1</sup> for the synthetic peptides (DENV/18) and 1.21 ng mL<sup>-1</sup> in CV and 0.43 ng mL<sup>-1</sup> in DPV for human serum, with a sensitivity of 7.21 µA in CV and 8.79 µA in DPV. The differentiation of infected and uninfected individuals was possible even at a high dilution factor that reduced the required sample volumes to a few microliters. The final device proved suitable for diagnosing DENV by analyzing real serum samples, and the results showed good agreement with molecular biology diagnostics. The flexibility to conjugate other antigenic peptides to SPEs suggests that this technology could be rapidly adapted to diagnose other pathogens.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-04-08
DOI
https://doi.org/10.3390/bios15040236
Citations
3
Primary Topic
Mosquito-borne diseases and control
Type
article
Field-Weighted Citation Impact
5.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasensitive Peptide-Based Electrochemical Biosensor for Universal Diagnostic of Dengue

Isis Prado, Paloma Napoleão-Pêgo, João Pedro Rangel da Silva Carvalho, André S. Araújo et al.
3 citations
Biosensors
Mosquito-borne diseases and control
5.64
article

Ultrasensitive Peptide-Based Electrochemical Biosensor for Universal Diagnostic of Dengue

Isis Prado, Paloma Napoleão-Pêgo, João Pedro Rangel da Silva Carvalho, André S. Araújo, Salvatore G. De-Simone
article en
3 citations

Abstract

Dengue is a neglected disease mainly affecting tropical and subtropical countries. The diagnosis of dengue fever is still a problem since most of it is made from whole or recombinant DENV proteins, which present cross-reactions with other members of the Flavivirus family. Therefore, there is still a huge demand for new diagnostic methods that provide rapid, low-cost, easy-to-use confirmation. Thus, in this study, we developed an affordable electrochemical biosensor for rapidly detecting immunoglobulin G (IgG) serological antibodies in the sera of DENV-infected patients. An identified linear B-cell epitope (DENV/18) specific for DENV 1-4 serotypes recognized by IgG in patient sera was selected as a target molecule after a microarray of peptides using the SPOT-synthesis methodology. After chemical synthesis, the DENV/18-peptide was immobilized on the surface of the working electrode of a commercially available screen-printed gold electrode (SPGE). The capture of DENV-specific IgG allowed for the formation of an immunocomplex that was measured by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) using a potassium ferrocyanide/ferricyanide ([Fe(CN)<sub>6</sub>]<sup>3-/4-</sup>) electrochemical probe. An evaluation of the biosensor's performance showed a detection limit of 100 µg mL<sup>-1</sup> for the synthetic peptides (DENV/18) and 1.21 ng mL<sup>-1</sup> in CV and 0.43 ng mL<sup>-1</sup> in DPV for human serum, with a sensitivity of 7.21 µA in CV and 8.79 µA in DPV. The differentiation of infected and uninfected individuals was possible even at a high dilution factor that reduced the required sample volumes to a few microliters. The final device proved suitable for diagnosing DENV by analyzing real serum samples, and the results showed good agreement with molecular biology diagnostics. The flexibility to conjugate other antigenic peptides to SPEs suggests that this technology could be rapidly adapted to diagnose other pathogens.

BiosensorsVol. 15(4)
Universidade Federal Fluminense (BR), Fundação Oswaldo Cruz (BR)
Fundação Oswaldo Cruz
Openalex Percentile: Top 5%
Mosquito-borne diseases and control
5.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.