Osteoarthritic Human Synovial Fluid Alters CoCrMo Electrochemical Properties on a Patient‐Specific Basis

Cobalt-chromium-molybdenum (CoCrMo) femoral components are widely used in total knee arthroplasty (TKA). However, recent retrospective clinical trials associate moderate adverse local tissue reactions with CoCrMo release in the knee. Additionally, gaps persist in our understanding of the fundamental corrosion processes that occur at the CoCrMo-synovial fluid interface. In this study, we investigated the electrochemical behavior of CoCrMo in human synovial fluid obtained at the time of primary TKA, using CoCrMo in phosphate-buffered saline (PBS) as a comparison. Synovial fluid was collected from 118 patients immediately before arthroplasty, then transferred to a three-electrode electrochemical cell with a wrought CoCrMo alloy working electrode. To quantify electrochemical properties, open circuit potential (OCP), electrochemical impedance spectroscopy, and linear polarization tests were run. Generally, the properties varied on a patient-by-patient basis and significantly differed (p < 0.05) from comparison tests performed in PBS. In human synovial fluid, we measured OCPs between a range of -0.38 and 0.15 V and corrosion potentials (E<sub>corr</sub>) between -0.95 and -0.2 V. Additionally, we reported instantaneous corrosion rates (1/R<sub>p</sub>) spanning nearly four orders of magnitude. The variability we documented suggested that the electrochemical properties of CoCrMo implants may depend on the patient's local physiological environment, influenced by the biological and chemical components of synovial fluid. Statement of Clinical Significance: This study shows that human synovial fluid affects the electrochemical behavior of CoCrMo, evidenced by the variation on a patient-by-patient basis. This study may have implications for long-term biological response to orthopaedic implants, including total knee arthroplasty.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2025-04-07
DOI
https://doi.org/10.1002/jor.26079
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Osteoarthritic Human Synovial Fluid Alters CoCrMo Electrochemical Properties on a Patient‐Specific Basis

John R. Crockarell, Marc J. Mihalko, Michael A. Kurtz, William M. Mihalko et al.
Journal of Orthopaedic Research®
Orthopaedic implants and arthroplasty
article

Osteoarthritic Human Synovial Fluid Alters CoCrMo Electrochemical Properties on a Patient‐Specific Basis

John R. Crockarell, Marc J. Mihalko, Michael A. Kurtz, William M. Mihalko, Bailey Bond, James L. Guyton, Christopher T. Holland, Madison N Brown, Abner Robinson
article en

Abstract

Cobalt-chromium-molybdenum (CoCrMo) femoral components are widely used in total knee arthroplasty (TKA). However, recent retrospective clinical trials associate moderate adverse local tissue reactions with CoCrMo release in the knee. Additionally, gaps persist in our understanding of the fundamental corrosion processes that occur at the CoCrMo-synovial fluid interface. In this study, we investigated the electrochemical behavior of CoCrMo in human synovial fluid obtained at the time of primary TKA, using CoCrMo in phosphate-buffered saline (PBS) as a comparison. Synovial fluid was collected from 118 patients immediately before arthroplasty, then transferred to a three-electrode electrochemical cell with a wrought CoCrMo alloy working electrode. To quantify electrochemical properties, open circuit potential (OCP), electrochemical impedance spectroscopy, and linear polarization tests were run. Generally, the properties varied on a patient-by-patient basis and significantly differed (p < 0.05) from comparison tests performed in PBS. In human synovial fluid, we measured OCPs between a range of -0.38 and 0.15 V and corrosion potentials (E<sub>corr</sub>) between -0.95 and -0.2 V. Additionally, we reported instantaneous corrosion rates (1/R<sub>p</sub>) spanning nearly four orders of magnitude. The variability we documented suggested that the electrochemical properties of CoCrMo implants may depend on the patient's local physiological environment, influenced by the biological and chemical components of synovial fluid. Statement of Clinical Significance: This study shows that human synovial fluid affects the electrochemical behavior of CoCrMo, evidenced by the variation on a patient-by-patient basis. This study may have implications for long-term biological response to orthopaedic implants, including total knee arthroplasty.

Journal of Orthopaedic Research®Vol. 43(6)
University of Tennessee Health Science Center (US), Campbell Clinic (US), Drexel University (US)
National Science Foundation, University of Pennsylvania, Orthopaedic Research Society, Heron Therapeutics, American Association of Hip and Knee Surgeons, Pacira BioSciences, U.S. Food and Drug Administration
Openalex Percentile: Top 88%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.