Au/Go Based Partially Uncladded SMF for Detection of Glucose Concentration

The determination of glucose concentrations in the blood and urine were important to monitor the health of human being. This study was carried out to study the effect GO thicknesses in enhancing the sensitivity of the Au/GO sensor for detection of glucose with various concentration. The partial unclad SMF was fabricated by using low-cost mechanical etching technique. The cladding thickness was successfully reduced from 125μm to 124μm by using this technique. To enhance the strength of evanescent field, Au nanoparticles were deposited on top of unclad fiber via drop casting method. To excite surface plasmon polaritons. GO with various layers from one to five layers were coated on the Au coated partial unclad SMF. The optimum sensitivity of the Au/GO SMF was resulted as three layers of GO with laser excitation under infrared range, λ=1310nm was employed. In conclusion, the effect of GO thicknesses mainly influenced the performance of the proposed sensor, in which the best thickness of GO to enhance the evanescent field and the excitation of SPP is three layers.

Authors

Institutions

Publication Details

Journal
Applied Mechanics and Materials
Published
2025-04-07
DOI
https://doi.org/10.4028/p-4lw10j
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Au/Go Based Partially Uncladded SMF for Detection of Glucose Concentration

Affa Rozana Abdul Rashid, Wan Maisarah Mukhtar, Nur Athirah Mohd Taib, Razman Mohd Halim et al.
2 links
Applied Mechanics and Materials
Electrochemical sensors and biosensors
article

Au/Go Based Partially Uncladded SMF for Detection of Glucose Concentration

Affa Rozana Abdul Rashid, Wan Maisarah Mukhtar, Nur Athirah Mohd Taib, Razman Mohd Halim, Nurulshahida Syafinie Fauzi
article en

Abstract

The determination of glucose concentrations in the blood and urine were important to monitor the health of human being. This study was carried out to study the effect GO thicknesses in enhancing the sensitivity of the Au/GO sensor for detection of glucose with various concentration. The partial unclad SMF was fabricated by using low-cost mechanical etching technique. The cladding thickness was successfully reduced from 125μm to 124μm by using this technique. To enhance the strength of evanescent field, Au nanoparticles were deposited on top of unclad fiber via drop casting method. To excite surface plasmon polaritons. GO with various layers from one to five layers were coated on the Au coated partial unclad SMF. The optimum sensitivity of the Au/GO SMF was resulted as three layers of GO with laser excitation under infrared range, λ=1310nm was employed. In conclusion, the effect of GO thicknesses mainly influenced the performance of the proposed sensor, in which the best thickness of GO to enhance the evanescent field and the excitation of SPP is three layers.

Applied Mechanics and MaterialsVol. 925
Universiti Sains Islam Malaysia (MY), Sirim Berhad (MY)
Openalex Percentile: Top 95%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies