Chiral LC method development for stereo-selective separation and quantification of Ivosidenib and its S,R and R,R isomeric impurities in drug substance and finished product

A robust and reliable chiral HPLC method was developed and validated for the separation and quantification of ivosidenib and its stereoisomeric impurities (S,R and R,R forms) in pharmaceutical formulations and bulk drug samples. The study optimized various analytical parameters including the mobile phase composition, pH modifiers, flow rate, detector wavelength and column temperature. A mobile phase comprising of methanol and 0.1% formic acid in 65:35 (v/v) ratio, with a flow rate of 0.8 mL/min and a detection wavelength of 248 nm, was identified as optimal. These conditions provided high-resolution symmetrical peaks with retention times of 6.5, 5.7 and 4.8 minutes for ivosidenib, S,R and R,R impurities respectively, ensuring a total analysis time of 10 minutes. System suitability parameters including peak resolution and retention time reproducibility, were within acceptable limits. Linearity studies demonstrated a strong correlation (R² > 0.999) for ivosidenib (25–250 μg/mL) and its impurities (0.25–2.50 μg/mL). Sensitivity analysis revealed detection limits as low as 0.075 μL/mL for the impurities. Accuracy studies across multiple concentrations showed recovery rates within 98–102%, with low relative standard deviations, indicating the method's high precision and reproducibility. Robustness testing confirmed the method's reliability. Stability studies validated that ivosidenib and its isomeric impurities remained stable for at least 15 days under both room temperature (25°C) and refrigeration (2°C) conditions. The results demonstrated compliance with pharmacopoeial standards, with ivosidenib content at 99.15% and impurity levels below the detection limit, confirming the stereoselective efficiency of the formulation. The method’s reliability, simplicity and applicability to both bulk batch and formulation samples make it an essential tool for pharmaceutical quality assurance.

Authors

Publication Details

Journal
Research Journal of Chemistry and Environment
Published
2025-02-28
DOI
https://doi.org/10.25303/294rjce079085
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Chiral LC method development for stereo-selective separation and quantification of Ivosidenib and its S,R and R,R isomeric impurities in drug substance and finished product

Bhagya Kumar Tatavarti, Venkata Swamy Tangeti, Rani Usha, Bhavani K. Tulasi
Research Journal of Chemistry and Environment
Analytical Chemistry and Chromatography
article

Chiral LC method development for stereo-selective separation and quantification of Ivosidenib and its S,R and R,R isomeric impurities in drug substance and finished product

Bhagya Kumar Tatavarti, Venkata Swamy Tangeti, Rani Usha, Bhavani K. Tulasi
article en

Abstract

A robust and reliable chiral HPLC method was developed and validated for the separation and quantification of ivosidenib and its stereoisomeric impurities (S,R and R,R forms) in pharmaceutical formulations and bulk drug samples. The study optimized various analytical parameters including the mobile phase composition, pH modifiers, flow rate, detector wavelength and column temperature. A mobile phase comprising of methanol and 0.1% formic acid in 65:35 (v/v) ratio, with a flow rate of 0.8 mL/min and a detection wavelength of 248 nm, was identified as optimal. These conditions provided high-resolution symmetrical peaks with retention times of 6.5, 5.7 and 4.8 minutes for ivosidenib, S,R and R,R impurities respectively, ensuring a total analysis time of 10 minutes. System suitability parameters including peak resolution and retention time reproducibility, were within acceptable limits. Linearity studies demonstrated a strong correlation (R² > 0.999) for ivosidenib (25–250 μg/mL) and its impurities (0.25–2.50 μg/mL). Sensitivity analysis revealed detection limits as low as 0.075 μL/mL for the impurities. Accuracy studies across multiple concentrations showed recovery rates within 98–102%, with low relative standard deviations, indicating the method's high precision and reproducibility. Robustness testing confirmed the method's reliability. Stability studies validated that ivosidenib and its isomeric impurities remained stable for at least 15 days under both room temperature (25°C) and refrigeration (2°C) conditions. The results demonstrated compliance with pharmacopoeial standards, with ivosidenib content at 99.15% and impurity levels below the detection limit, confirming the stereoselective efficiency of the formulation. The method’s reliability, simplicity and applicability to both bulk batch and formulation samples make it an essential tool for pharmaceutical quality assurance.

Research Journal of Chemistry and EnvironmentVol. 29(4)
Openalex Percentile: Top 93%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Chiral LC method development for stereo-selective separation and quantification of Ivosidenib and its S,R and R,R isomeric impurities in drug substance and finished product — Bhagya Kumar Tatavarti, Venkata Swamy Tangeti, et al. · Research Journal of Chemistry and Environment (2025) | TGRS Research Map | TGRS