Self-Calibrated Stitching Test of X-Ray Flat Mirrors for Achieving Single-Nanometer and Nanoradian Long-Term Reproductivity

X-ray flat surfaces utilized in most advanced light sources have posed challenges to achieve form accuracy of PV 2 nm, RMS 0.2 nm and RMS 50 nrad. Measurement of the form error with high long-term reproductivity, i.e., repeatability over time of at least one day and with test surface re-mounted, is the key to direct deterministic figuring process. For this end, the models of two main error sources – long-term environment disturbance and retrace error have been established. The different error periods components of the long-term environment disturbance and their influence on the full aperture test accuracy has been investigated. The method of determining the adequate sub-aperture size, overlapping ratio, and the tilt misalignment threshold for decreasing the influence of the long-term environment disturbance and the retrace error is reported. The PV value standard uncertainty is evaluated to be 0.092 nm. Experiments on an X-ray flat with clear aperture of 250 mm × 30 mm was tested with the optimized test parameters and other sets of parameters for comparisons. Self-consistency experiments have been conducted to verify the long-term reproductivity can reach PV 0.908 nm, RMS 0.076 nm and RMS 32 nrad which meet the typical test accuracy posed by the 4th generation synchrotron radiation and free electron lasers.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3556163
Citations
5
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
9.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Calibrated Stitching Test of X-Ray Flat Mirrors for Achieving Single-Nanometer and Nanoradian Long-Term Reproductivity

Antong Huang, Z. L. Chen, Yong Liu, Shuai Xue et al.
5 citations
IEEE Transactions on Instrumentation and Measurement
Advanced X-ray Imaging Techniques
9.41
article

Self-Calibrated Stitching Test of X-Ray Flat Mirrors for Achieving Single-Nanometer and Nanoradian Long-Term Reproductivity

Antong Huang, Z. L. Chen, Yong Liu, Shuai Xue, Yunfeng Mao, Zubo Hu
article en
5 citations

Abstract

X-ray flat surfaces utilized in most advanced light sources have posed challenges to achieve form accuracy of PV 2 nm, RMS 0.2 nm and RMS 50 nrad. Measurement of the form error with high long-term reproductivity, i.e., repeatability over time of at least one day and with test surface re-mounted, is the key to direct deterministic figuring process. For this end, the models of two main error sources – long-term environment disturbance and retrace error have been established. The different error periods components of the long-term environment disturbance and their influence on the full aperture test accuracy has been investigated. The method of determining the adequate sub-aperture size, overlapping ratio, and the tilt misalignment threshold for decreasing the influence of the long-term environment disturbance and the retrace error is reported. The PV value standard uncertainty is evaluated to be 0.092 nm. Experiments on an X-ray flat with clear aperture of 250 mm × 30 mm was tested with the optimized test parameters and other sets of parameters for comparisons. Self-consistency experiments have been conducted to verify the long-term reproductivity can reach PV 0.908 nm, RMS 0.076 nm and RMS 32 nrad which meet the typical test accuracy posed by the 4th generation synchrotron radiation and free electron lasers.

IEEE Transactions on Instrumentation and MeasurementVol. 74
National University of Defense Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Hunan Province, State Key Laboratory of High Performance Complex Manufacturing
Openalex Percentile: Top 2%
Advanced X-ray Imaging Techniques
9.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Self-Calibrated Stitching Test of X-Ray Flat Mirrors for Achieving Single-Nanometer and Nanoradian Long-Term Reproductivity — Antong Huang, Z. L. Chen, et al. · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS