Thermal Distribution and Airflow in Data CentreAt Uthm:Pusat Teknologi Maklumat, Block A5

This research work is concerned with the investigation of thermal management and air circulation in the data centre at Universiti Tun Hussein Onn Malaysia, which is situated in Block A5. The facility has no windows, natural ventilation, or air conditioning systems, making it difficult to achieve and maintain appropriate temperatures for storing and processing data. The disparity in temperature felt in the centre called for enhancing the cooling systems as a means of enhancing the efficiency and durability of the equipment. The simulations focused on temperature distributions at different heights of the data centre, including the middle of the room and at one-quarter and half heights. Furthermore, the rack cooling index (RCI) was used to measure the rack cooling performance in accordance with the ASHRAE guidelines on data centre cooling. The results revealed significant variations in the temperature pattern, with some server racks having higher heat densities and the cooling units nearby having to work harder to achieve the set temperatures. Such an imbalance in the cooling system requires strategic changes. To improve the cooling performance, specific suggestions were made, such as increasing the airflow from some air-conditioning units to address hot spots. These changes should help mitigate moderate temperature fluctuations within the data centre and in turn improve the efficiency of the cooling system. The proposed strategies for controlling the airflow and cooling aim at reducing the energy consumption and increasing the lifespan of critical server components. Finally, this study highlightsthe need for customized cooling systems in data centres and offers practical recommendations for enhancing the sustainability of data centre cooling systems.

Authors

Institutions

Publication Details

Journal
Journal of Advances in Fluid Heat and Materials Engineering
Published
2025-04-07
DOI
https://doi.org/10.37934/afhme.3.1.19a
Primary Topic
Blockchain Technology in Education and Learning
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Distribution and Airflow in Data CentreAt Uthm:Pusat Teknologi Maklumat, Block A5

Ishkrizat Taib, Amir Farid Ismail, M. Mohamed, Norinah Abd Rahman et al.
Journal of Advances in Fluid Heat and Materials Engineering
Blockchain Technology in Education and Learning
article

Thermal Distribution and Airflow in Data CentreAt Uthm:Pusat Teknologi Maklumat, Block A5

Ishkrizat Taib, Amir Farid Ismail, M. Mohamed, Norinah Abd Rahman, Muhammad Ammar Baharuddin
article en

Abstract

This research work is concerned with the investigation of thermal management and air circulation in the data centre at Universiti Tun Hussein Onn Malaysia, which is situated in Block A5. The facility has no windows, natural ventilation, or air conditioning systems, making it difficult to achieve and maintain appropriate temperatures for storing and processing data. The disparity in temperature felt in the centre called for enhancing the cooling systems as a means of enhancing the efficiency and durability of the equipment. The simulations focused on temperature distributions at different heights of the data centre, including the middle of the room and at one-quarter and half heights. Furthermore, the rack cooling index (RCI) was used to measure the rack cooling performance in accordance with the ASHRAE guidelines on data centre cooling. The results revealed significant variations in the temperature pattern, with some server racks having higher heat densities and the cooling units nearby having to work harder to achieve the set temperatures. Such an imbalance in the cooling system requires strategic changes. To improve the cooling performance, specific suggestions were made, such as increasing the airflow from some air-conditioning units to address hot spots. These changes should help mitigate moderate temperature fluctuations within the data centre and in turn improve the efficiency of the cooling system. The proposed strategies for controlling the airflow and cooling aim at reducing the energy consumption and increasing the lifespan of critical server components. Finally, this study highlightsthe need for customized cooling systems in data centres and offers practical recommendations for enhancing the sustainability of data centre cooling systems.

Journal of Advances in Fluid Heat and Materials EngineeringVol. 3(1)
Tun Hussein Onn University of Malaysia (MY)
Universiti Tun Hussein Onn Malaysia
Openalex Percentile: Top 92%
Blockchain Technology in Education and Learning
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.