Large-scale timing synchronization based on linear-optics timing detectors
Abstract We presented an attosecond-precision timing detector based on linear optics. The minimum measurement floor is 1×10 –10 fs 2 /Hz with only 1 mW input optical power. With this novel technique, the residual dispersion of a 5.2 km fiber link is characterized and precisely compensated. Finally, a comprehensive feedback model has been developed to analyze the noise coupling in a long-distance link stabilization system. The simulation results demonstrate an out-of-loop jitter of merely 359 as, integrated at [1 Hz, 1 MHz], at 1 mW input power per photodetector of our timing detector. Remarkably, the system is capable of maintaining sub-femtosecond precision even at optical power levels as low as 240 nW (for a 5.2 km link length), or link lengths as long as 20 km (with 1 μW optical power), respectively.
Authors
- Pan De-hui
- Jian Yang (ORCID: https://orcid.org/0000-0003-4887-3444)
- Haoyang Sun (ORCID: https://orcid.org/0000-0002-0176-0453)
- Ke Zhang (ORCID: https://orcid.org/0000-0001-8152-3062)
- Yi Zhang (ORCID: https://orcid.org/0000-0003-0859-9735)
- Yulin Shen (ORCID: https://orcid.org/0000-0003-3770-0660)
- Mingzhe Li (ORCID: https://orcid.org/0000-0001-5598-7664)
- Tong Wang (ORCID: https://orcid.org/0009-0002-8589-2652)
- Ming Xin (ORCID: https://orcid.org/0000-0002-1809-1815)
- Jiahui Yao
Institutions
- Tianjin University (CN)
- Shanghai Center for Brain Science and Brain-Inspired Technology (CN)
Publication Details
- Journal
- High Power Laser Science and Engineering
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1017/hpl.2025.30
- Primary Topic
- Network Time Synchronization Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China