ECG Sensor Design Assessment with Variational Autoencoder-Based Digital Watermarking

Designing an ECG sensor circuit requires a comprehensive approach to detect, amplify, filter, and condition the weak electrical signals produced by the heart. To evaluate sensor performance under realistic conditions, diverse ECG signals with embedded watermarks are generated, enabling an assessment of how effectively the sensor and its signal-conditioning circuitry handle these modified signals. A Variational Autoencoder (VAE) framework is employed to generate the watermarked ECG signals, addressing critical concerns in the digital era, such as data security, authenticity, and copyright protection. Three watermarking strategies are examined in this study: embedding watermarks in the mean (μ) of the VAE's latent space, embedding them through the latent variable (z), and using post-reconstruction watermarking in the frequency domain. Experimental results demonstrate that watermarking applied through the mean (μ) and in the frequency domain achieves a low Mean Squared Error (MSE) while maintaining stable signal fidelity across varying watermark strengths (α), latent space dimensions, and noise levels. These findings indicate that the mean (μ) and frequency domain methods offer robust performance and are minimally affected by changes in these parameters, making them particularly suitable for preserving ECG signal quality. By contrasting these methods, this study provides insights into selecting the most appropriate watermarking technique for ECG sensor applications. Incorporating watermarking into sensor design not only strengthens data security and authenticity but also supports reliable signal acquisition in modern healthcare environments. Overall, the results underscore the effectiveness of combining VAEs with watermarking strategies to produce high-fidelity, resilient ECG signals for both sensor performance evaluation and the protection of digital content.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-04-05
DOI
https://doi.org/10.3390/s25072321
Citations
1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ECG Sensor Design Assessment with Variational Autoencoder-Based Digital Watermarking

Yin-Chi Chen, Shuo-Tsung Chen, Jingxian Wu, Chun‐Chieh Chang et al.
1 citations
Sensors
ECG Monitoring and Analysis
1.39
article

ECG Sensor Design Assessment with Variational Autoencoder-Based Digital Watermarking

Yin-Chi Chen, Shuo-Tsung Chen, Jingxian Wu, Chun‐Chieh Chang, Chih‐Yu Hsu
article en
1 citations

Abstract

Designing an ECG sensor circuit requires a comprehensive approach to detect, amplify, filter, and condition the weak electrical signals produced by the heart. To evaluate sensor performance under realistic conditions, diverse ECG signals with embedded watermarks are generated, enabling an assessment of how effectively the sensor and its signal-conditioning circuitry handle these modified signals. A Variational Autoencoder (VAE) framework is employed to generate the watermarked ECG signals, addressing critical concerns in the digital era, such as data security, authenticity, and copyright protection. Three watermarking strategies are examined in this study: embedding watermarks in the mean (μ) of the VAE's latent space, embedding them through the latent variable (z), and using post-reconstruction watermarking in the frequency domain. Experimental results demonstrate that watermarking applied through the mean (μ) and in the frequency domain achieves a low Mean Squared Error (MSE) while maintaining stable signal fidelity across varying watermark strengths (α), latent space dimensions, and noise levels. These findings indicate that the mean (μ) and frequency domain methods offer robust performance and are minimally affected by changes in these parameters, making them particularly suitable for preserving ECG signal quality. By contrasting these methods, this study provides insights into selecting the most appropriate watermarking technique for ECG sensor applications. Incorporating watermarking into sensor design not only strengthens data security and authenticity but also supports reliable signal acquisition in modern healthcare environments. Overall, the results underscore the effectiveness of combining VAEs with watermarking strategies to produce high-fidelity, resilient ECG signals for both sensor performance evaluation and the protection of digital content.

SensorsVol. 25(7)
University of Kang Ning (TW), National Kaohsiung University of Science and Technology (TW), Fujian University of Technology (CN), Chung Shan Medical University (TW)
Openalex Percentile: Top 21%
ECG Monitoring and Analysis
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.