Techno-economic and environmental assessment of a moderately high-temperature heat pump prototype using R-450A across diverse operational conditions and heat sources

Decarbonizing the industrial sector requires the adoption of efficient electric-driven energy conversion systems, and high-temperature heat pumps may offer a viable alternative. This study presents an energy, environmental, and economic assessment of an industrial heat pump prototype using R-450A for 85 °C process heating, comparing it with a traditional natural gas-fired boiler. Twenty-seven steady-state heat pump operational conditions are examined. Simulation analysis is then performed across thirty-two scenarios using multi-variable linear regression models built on the results of experimental tests. The conditions investigated vary in heat pump control strategy, configuration (with or without an internal heat exchanger), and heat source (different generations of district heating networks, district cooling networks, or air). One-year-long simulations are carried out on an hourly basis, considering the air-source heat pump installed in six Italian cities. The results highlight that maximizing compressor frequency reduces heat pump performance, which also decreases with an increasing pressure ratio when the condensation temperature is set. While carbon dioxide emissions are always avoided compared to the traditional boiler, a trade-off is required between the heat pump's energy, environmental, and economic performance. The best-performing configuration results in approximately 5 % primary energy saving, 31 % carbon dioxide emissions avoided, and 30 % operational cost reduction. • Experimental analysis of a moderately high-temperature heat pump using R-450A. • Multi-variable empirical modelling based on the results of experimental tests. • Evaporation and condensation temperatures up to 40 and 85 °C, respectively. • Best performance achieved with controlled heating capacity and internal heat exchanger on.

Authors

Institutions

Publication Details

Journal
Energy
Published
2025-04-07
DOI
https://doi.org/10.1016/j.energy.2025.136008
Citations
4
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
2.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Techno-economic and environmental assessment of a moderately high-temperature heat pump prototype using R-450A across diverse operational conditions and heat sources

Adrián Mota-Babiloni, Elisa Marrasso, Giovanna Pallotta, Maurizio Sasso et al.
4 citations
Energy
Refrigeration and Air Conditioning Technologies
2.85
article

Techno-economic and environmental assessment of a moderately high-temperature heat pump prototype using R-450A across diverse operational conditions and heat sources

Adrián Mota-Babiloni, Elisa Marrasso, Giovanna Pallotta, Maurizio Sasso, Joaquín Navarro-Esbrí, Ghad Alarnaot-Alarnaout
article en
4 citations

Abstract

Decarbonizing the industrial sector requires the adoption of efficient electric-driven energy conversion systems, and high-temperature heat pumps may offer a viable alternative. This study presents an energy, environmental, and economic assessment of an industrial heat pump prototype using R-450A for 85 °C process heating, comparing it with a traditional natural gas-fired boiler. Twenty-seven steady-state heat pump operational conditions are examined. Simulation analysis is then performed across thirty-two scenarios using multi-variable linear regression models built on the results of experimental tests. The conditions investigated vary in heat pump control strategy, configuration (with or without an internal heat exchanger), and heat source (different generations of district heating networks, district cooling networks, or air). One-year-long simulations are carried out on an hourly basis, considering the air-source heat pump installed in six Italian cities. The results highlight that maximizing compressor frequency reduces heat pump performance, which also decreases with an increasing pressure ratio when the condensation temperature is set. While carbon dioxide emissions are always avoided compared to the traditional boiler, a trade-off is required between the heat pump's energy, environmental, and economic performance. The best-performing configuration results in approximately 5 % primary energy saving, 31 % carbon dioxide emissions avoided, and 30 % operational cost reduction. • Experimental analysis of a moderately high-temperature heat pump using R-450A. • Multi-variable empirical modelling based on the results of experimental tests. • Evaporation and condensation temperatures up to 40 and 85 °C, respectively. • Best performance achieved with controlled heating capacity and internal heat exchanger on.

EnergyVol. 326
Universitat Jaume I (ES), University of Sannio (IT)
European Commission, Universitat Jaume I
Openalex Percentile: Top 10%
Refrigeration and Air Conditioning Technologies
2.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.