Development and validation of a reverse - phase high - performance liquid chromatography method for indacaterol and budesonide analysis

An efficient, precise, and accurate technique for the concurrent estimation of compounds Indacaterol and Budesonide in pharmaceutical preparations were developed. The analysis utilized an Xterra C18 (4.6 × 150 mm, 5.0 μm) chromatographic column used in combination with a mobile phase ratio of buffer (0.1% orthophosphoric acid): acetonitrile (40:60% v/v) and a flow rate is 1 mL/min. The detection was perfo rmed at a wavelength of 220 nm. The recorded retention times for Indacaterol and Budesonide were 3.124 minutes and 4.270 minutes, respectively. Respectively. The percentage recovery was 100.01% for Indacaterol and 100.34% for Budesonide. The method demonst rated limits of detection (LOD) of 0.3 μg/mL and 0.6 μg/mL and limits of quantification (LOQ) of 1.0 μg/mL and 1.9 μg/mL for Indacaterol and Budesonide. Regression equations confirmed linearity within the established range. Stress degradation studies (acid , base, peroxide, thermal, and photostability conditions) indicated that the percentage degradation of Indacaterol and Budesonide remained within acceptable limits, ensuring method robustness .

Authors

Publication Details

Journal
Future Journal of Pharmaceuticals and Health Sciences
Published
2025-04-01
DOI
https://doi.org/10.26452/fjphs.v5i2.725
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of a reverse - phase high - performance liquid chromatography method for indacaterol and budesonide analysis

P. Jeevan Kumar, C. Gopinath
Future Journal of Pharmaceuticals and Health Sciences
Analytical Methods in Pharmaceuticals
article

Development and validation of a reverse - phase high - performance liquid chromatography method for indacaterol and budesonide analysis

P. Jeevan Kumar, C. Gopinath
article en

Abstract

An efficient, precise, and accurate technique for the concurrent estimation of compounds Indacaterol and Budesonide in pharmaceutical preparations were developed. The analysis utilized an Xterra C18 (4.6 × 150 mm, 5.0 μm) chromatographic column used in combination with a mobile phase ratio of buffer (0.1% orthophosphoric acid): acetonitrile (40:60% v/v) and a flow rate is 1 mL/min. The detection was perfo rmed at a wavelength of 220 nm. The recorded retention times for Indacaterol and Budesonide were 3.124 minutes and 4.270 minutes, respectively. Respectively. The percentage recovery was 100.01% for Indacaterol and 100.34% for Budesonide. The method demonst rated limits of detection (LOD) of 0.3 μg/mL and 0.6 μg/mL and limits of quantification (LOQ) of 1.0 μg/mL and 1.9 μg/mL for Indacaterol and Budesonide. Regression equations confirmed linearity within the established range. Stress degradation studies (acid , base, peroxide, thermal, and photostability conditions) indicated that the percentage degradation of Indacaterol and Budesonide remained within acceptable limits, ensuring method robustness .

Future Journal of Pharmaceuticals and Health SciencesVol. 5(2)
Openalex Percentile: Top 93%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and validation of a reverse - phase high - performance liquid chromatography method for indacaterol and budesonide analysis — P. Jeevan Kumar, C. Gopinath · Future Journal of Pharmaceuticals and Health Sciences (2025) | TGRS Research Map | TGRS